- 75 -
ATC replacement operation timing (KE-750)
When detaching
When attaching
Move to ATC
Standby
position
Laser
height
ATC
replacement
height
Move
X-Y
Stop
Nozzle YES/NO
check
Lift up
Z axis Stop
Lift down
Open
Slide plate
Close
ON
Open sensor
OFF
ON
Close sensor
OFF
ON
Vac
OFF
ON
Blow
OFF
Standby
position
Laser
height
Standby
position
Move
X-Y
Stop
Nozzle YES/NO
check
Lift up
Z axis Stop
Lift down
Open
Slide plate
Close
ON
Open sensor
OFF
ON
Close sensor
OFF
ON
Vac
OFF
ON
Blow
OFF
Move to ATC
Standby
position
Standby
position
Standby
position
Laser
height
Laser
height
ATC
replacement
height
NOTE: Time in parentheses ( ) is an assumed value.
NOTE: When both are replaced at the same time, the next
sequence occurs using the axis which is the longest
one for the pulse of Z axis to complete as the trigger.
- 76 -
ATC replacement operation timing (KE-760) Replacement of the nozzle dedicated to the laser
When detaching When attaching
Move
X-Y
Stop
Nozzle YES/NO
check
Lift up
Z axis Stop
Lift down
Open
Slide plate
Close
ON
Open sensor
OFF
ON
Close sensor
OFF
ON
Vac
OFF
ON
Blow
OFF
Move
X-Y
Stop
Nozzle YES/NO
check
Lift up
Z axis Stop
Lift down
Open
Slide plate
Close
ON
Open sensor
OFF
ON
Close sensor
OFF
ON
Vac
OFF
ON
Blow
OFF
Standby
position
Laser
height
ATC
replacement
height
Move to ATC
NOTE: Time in parentheses ( ) is an assumed value.
NOTE: When both are replaced at the same time, the next
sequence occurs using the axis which is the longest
one for the pulse of Z axis to complete as the trigger.
Laser
height
Standby
position
Standby
position
Move to ATC
Standby
position
Laser
height
ATC
replacement
height
Standby
position
Standby
position
Laser
height
- 77 -
3.3.2 Nozzle replacement check
Before and after detaching the nozzle and also before and after attaching the
nozzle, laser align is performed to check whether the nozzle is installed in the Z
slider shaft (nozzle YES/NO check), and to check whether its operation has
been performed correctly.
For items q, w, and e for detaching and attaching, at 10 mm below the laser
height of the nozzle, whether the nozzle is attached to the Z slider shaft is
roughly checked by Measure Once command.
For item q, whether the nozzle is attached is checked before detaching.
For items w and e, whether the nozzle is detached is checked after detaching
and before attaching.
For item r, whether or not the nozzle is correctly attached is checked as follows:
When the nozzle is attached, at 0.4 mm below the laser height of the nozzle,
the diameter of the nozzle at the tip is measured by Measure Once command.
The measured result is regarded as normal when the measured diameter
equals to the specified value. If different, it is regarded as not normal, and an
error message is displayed. When normal, to check that the nozzle is set in
the Z slider shaft, the nozzle is moved by 0.3 mm up from the laser height, and
whether the nozzle is attached is checked again by Measure Once command.
When the nozzle is not detected (Status: 64), the result is normal. For any
other statuses, an error message is displayed regarding that the nozzle is not
normally attached.
If so, possible cause is lack of grease at the O-ring in the Z slider shaft, or a
foreign matter left between the nozzle and the Z slider shaft. Apply grease or
clean out the foreign matter.