KE-750_MAINTE.pdf - 第69页

- 6 6 - This chart shows that board B i s manually placed a t WAIT position during production of board A . B.A.IN Ready OUT I N sensor WAIT sensor STOP sensor C.OUT sensor OUT sensor B U U P sensor B U D N sensor Stopper…

100%1 / 228
- 65 -
This chart shows that the last board of continuous production is carried out
or the board is carried out b
y
cancellation of
p
roduction.
(13)
B.A.IN
Ready OUT
IN sensor
WAIT sensor
STOP sensor
C.OUT sensor
OUT sensor
BU UP sensor
BU DN sensor
Stopper
Backup
External shape
cramp 1 (X)
IN motor
CENT motor
OUT motor
Ready IN
B.A.OUT
External shape
cramp 2 (Y)
Board carriage
Carriage, completed
If there is no board B when a carry out command is issued,
Ready OUT to the previous stage is set off (Busy).
[Key operation]
Operation by the board carry out command is effective only on the board
currently set in the centering station. It is not effective on the board to be
carried in from the IN buffer.
- 66 -
This chart shows that board B is manually placed at WAIT position during production of board A.
B.A.IN
Ready OUT
IN sensor
WAIT sensor
STOP sensor
C.OUT sensor
OUT sensor
BU UP sensor
BU DN sensor
Stopper
Backup
External shape
cramp 1 (X)
IN motor
CENT motor
OUT motor
Ready IN
B.A.OUT
Board carriage
External shape
cramp 2 (Y)
(14)
Placed manually.
Carriage, completed
[Key operation]
The status that the WAIT sensor is set on is reliable. Therefore, when th
e
WAIT sensor is set on, the IN buffer is set in "board loaded" condition eve
n
if the board is not carried into the IN buffer. However, this status is not
latched and if board B is removed during production of board A, the IN
buffer is set in "board unloaded" condition.
- 67 -
This chart shows that board B is manually set on the OUT sensor during production of board A.
(15)
B.A.IN
Ready OUT
IN sensor
WAIT sensor
STOP sensor
C.OUT sensor
OUT sensor
BU UP sensor
BU DN sensor
Stopper
Backup
External shape
cramp 1 (X)
IN motor
CENT motor
OUT motor
Ready IN
B.A.OUT
Board carriage
External shape
cramp 2 (Y)
[Key operation]
There is no latch status for the OUT buffer such as for the IN buffer,
and detection is made simply by on and off of the OUT sensor.