Vermes MDS 358X user Manual.pdf - 第100页

Communication Interfaces VTK - TR -BA- 072e - 1 - User Manua l MDS 358X S eries 89 5 ADJUS T:S TAR T Descript ion: Sending this c ommand causes the adjust to be exec uted at once. Th is procedu re chec ks on t he posit i…

100%1 / 195
Communication Interfaces
88
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
8.1.2.2 Explanations
0
1 *ESR? ESR? = Event Status Register Query
Description:
This command shows the latest error codes created by the system, starting
with the latest event. At the most 50 error messages will be shown.
Each error messages also includes the valve ID (if known) and a time and
date stamp. If the RTC of the MDC is defect, the value will be given as
“00:00:00 2014-01-01”.
Example:
Input:
*ESR?
Result:
List of the (up to 50) latest error messages
Return:
8 199 valve error 08FU04 09:16:38 2018-01-21
9 101 wrong valve 08FU04 09:16:21 2018-01-21
2 *ESR2? ESR2? = Event Status Register Query 2
Description:
This command shows the latest error codes created by the system, starting
with the latest event. There will be shown a max of 50 error messages.
Each error messages also includes the valve ID (if known) and a time and
date stamp. If the RTC of the MDC is defect, the value will be given as
“00:00:00 2014-01-01”. Additionally the parameters of setups 0 to 3 before
the error are listed.
Example:
Input:
*ESR2?
Result:
List of the (up to 50) latest error messages with parameters
Return:
20 199 valve error 000000 09:16:38 2018-01-21
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
27 101 wrong valve 08FU04 09:16:21 2018-01-21
30, 5, 30, 80, 1, 20
50, 20, 20, 80, 1, 100
50, 20, 20, 80, 1, 100
50, 20, 20, 80, 1, 100
3 *IDN? IDN? = Identification Query
Description:
Device specific information, formatted as follows: type (hv or lv, high
viscosity or low viscosity systems), software version. Important for contact
with our Technical Support.
Example:
Input:
*IDN?
Result:
Micro Dispenser HV, 4085AA1-1
Return:
Micro Dispenser HV, 4085AA1-1
4 *OPC? OPC? = Operation Complete Query
Description:
Monitoring the last trigger impulses. After this, the counter is cleared to
zero.
Example:
Input:
*OPC?
Result:
Number of the last pulses. Clears the counter to zero.
Return:
6699
Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
89
5 ADJUST:START
Description:
Sending this command causes the adjust to be executed at once. This
procedure checks on the position of the nozzle insert with respect to the
tappet. It is required during each initial start-up and after replacing the
nozzle unit.
For further information read paragraph 8.2.3, page 117.
Example:
Input:
ADJUST:START
Result:
The adjust is initiated.
Return:
Adjust Screw OUT Press Enter
6 ADJUST:OFFSET:?
Description:
This command gives the current value of the adjust offset (see
paragraph 7.12, page 75).
The value can be between -5 and 5. The value 0 means, the adjust offset is
deactivated.
Example:
Input:
ADJUST:OFFSET:?
Result:
The current value of the adjust offset is returned.
Return:
5
7 ADJUST:OFFSET:<offset value>
Description:
This command sets the value for the adjust offset (see paragraph 7.12,
page 75).
You can enter integer values between -5 and 5. With 0 you deactivate the
adjust offset.
Example:
Input:
ADJUST:OFFSET:5
Result:
The value of the adjust offset is set (here: to 5).
Return:
OK
8 ADJUST:CALIBRATION:?
Description:
This command gives the status of the (remote) adjust and the current
adjust value. The response to this command contains seven numerical
values. You can ignore the first six parameters limit at 0 %, limit at 100 %,
difference, reference value, last mean value and total value). They are only
there for our support, if there is an error with the (remote) adjust.
The last parameter sent is the adjust value in percent. Be aware that the
given value is the actual percentage value, multiplied by 10. Therefore, a
given value of 8 represents an adjust value of 0.8 %.
Example:
Input:
ADJUST:CALIBRATION:?
Result:
The status of the (remote) adjust is given, including the
current adjust value.
Return:
151285, 47623, 103662, 150836, 108654, 42182, 8
9 ADJUST:CALIBRATION:ON
Description:
This command activates the adjust, so that you can perform it as a remote
adjust.
Example:
Input:
ADJUST:CALIBRATION:ON
Result:
The adjust is activated.
Return:
Adjust ON
Communication Interfaces
90
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
10 HEATER:?
Description:
This command shows the state of the heater. This includes the following
information.
T-point of the temperature calibration
M- point of the temperature calibration
Maximum temperature of the connected heater (°C)
the current target temperature (°C)
upper limit of allowed temperature range (°C x 10)
lower limit of allowed temperature range (°C x 10)
current temperature (°C)
calibration status (0 = no, 1 = yes)
current heater status (1 = ON, 2 = OFF, 4 = not
calibrated, 5 = temperature settled in, 7 = plugged in,
8 = plugged out, 9 = calibration 20 °C, 10 =
calibration 100 °C; XXXX communication error code)
In case there is no heater connected, the response is “NAK”.
Example:
Input:
HEATER:?
Result:
Switched ON or OFF, current temperature and target
temperature and other information are given.
Return:
1000, 20000, 180, 110, 30, 20, 109, 1, 5
11 HEATER:ID?
Description:
This command shows the type and serial number of the heater.
In case there is no heater connected, the response is “NAK”.
Example:
Input:
HEATER:ID?
Result:
Type and serial number of the heater are given.
Return:
MDH-48-BY, 10UB1234
12 HEATER:OFF
Description:
The connected heater is turned off.
In case there is no heater connected, the response is “NAK”.
Example:
Input:
HEATER:OFF
Result:
The connected heater is deactivated.
Return:
OK
13 HEATER:ON
Description:
The connected heater is turned on.
In case there is no heater connected, the response is “NAK”.
Example:
Input:
HEATER:ON
Result:
The connected heater is activated.
Return:
OK