Operation
82
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
7.15 Switching OFF the Microdispensing System
Step 1: The current dispensing cycle must be completed, so that the valve is in home position.
Step 2: Lower the supply pressure to atmospheric pressure (because in initial position, the
valve is still opened). Disengage the pneumatic supply. If required, close the cartridge by
using locking pin MDT 309.
Step 3: Switch OFF the control unit (ON/OFF button at the rear end). After switching OFF the
control unit, please wait a few seconds.
Step 4: Disconnect the valve from fluid supply.
Step 5: Remove all cables from the valve.
Step 6: Unscrew the screws used for fixing the valve in place.
After working with self-curing substances, immediate cleaning is advisable in order to avoid
clogging. This concerns the valve itself and all parts in contact with the fluid. The valve and its
subcomponents have to be dismantled and cleaned (see chapter 9, page 120).
Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
83
8 Communication Interfaces
The control unit has three communication interfaces. There is a 9-pin serial interface, RS-232C, a
15-pin PLC interface and an AUX socket.
8.1 Serial Interface RS-232C: 9-Pin Sub-D
Fig. 61: Serial interface
The local interface is structured according to SCPI Standard.
These “Standard Commands for Programmable Instruments” represent a standardized set of
instructions used for control and programming, transmitted in form of ASCII text. They can be
generated by any selectable programming language in any environment. The serial interface
operates by means of software handshake. The hardware handshake communications are not in
use.
INFORMATION
Communication while triggering
Do not send instructions through this interface in the course of a running dispensing cycle.
Communication is only possible between distinct sequences (signal DosOK on “high”). This is
especially important during start-up of a heater.
After sending data or parameters to the control unit, you have to wait for the “OK” signal before
you can start further actions. You only can send data while the MDC is in the main menu.
8.1.1 Pin Functions
PIN Characteristics Level Function
1 Reserved ___________ ___________
2
Output
TX
Serial transmission signal
3
Input
RX
Serial reception signal
4
Connected to PIN 6
5
Ground
Ground
6
Connected to PIN 4
7
Reserved
___________
___________
8
Reserved
___________
___________
9
Reserved
___________
___________
The RS-232C log of the control unit uses RS-232C standard and is designed for communication
via a serial cable, connected 1:1, with a Sub-D nine pin connector.
Communication Interfaces
84
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
The following parameter configuration is used for the communication with the control unit:
Synchronous mode: Half-duplex
Bits/s: 9600 115200 (5 different options available, see paragraph 4.5.6, page 37)
Start bit: 1
String length: 8 bit (ASCII)
Parity: None
Stop bit: 1
Log: None
8.1.2 RS-232C Commands
The available commands are listed below. They are explained on the following pages, together
with short examples. This list is according to firmware revision 4085AA1-C.
Each command has to be followed by a line feed (LF, \n, 0x0a) and then a carriage return (CR, \r,
0x0d). It is important to keep to this order!
INFORMATION
Response to commands
The control unit gives a response to every command send to her. Possible answers are:
A value or set of value, asked for in the command
OK, to acknowledge a command sent
NAK (“not acknowledged”), if command sent was incorrect (e.g. incomplete set of values or a
value outside the range, or after start-up a wrong command while the display shows the
message “Please do Adjust”)
“Auxiliary Mode”, if you send the command “SYSTEM:SHOW:VALVEID” while the system is in
the auxiliary mode.
If there is no response to a command, either the connection is interrupted (e.g. malfunctioning
cable or interface) or the command did not end in a carriage return (0x0d).
The reaction times for the commands are given in the table in the next chapter. The table lists the
values for the highest and lowest baud rate, since these have a great influence on the times. The
length of a response is also influential. There it makes e.g. a big difference with the ESR
commands, if there are only a few errors reported or many of them. Please be aware that your
hardware also influences the reaction times. Therefore, the given times are only guidelines.