Error code display:
905 Setup Load Error pr. Enter
Error code status menu:
905 Setup Load Error
Error handling:
Press [enter] key to acknowledge error message
Repeat the procedure. If the problem persists, you have
to enter new data to the corresponding memory
position.
In case the error appears again, send the MDC to
VERMES Microdispensing or to your supplier
Valve:
Valve remains unchanged. If the error message appears
during the start of the MDC, the valve is open, otherwise it
is closed.
999 999 Error in Errorlist
The problem cannot be assigned to any other error code from the list. This error only appears
while browsing through the error list in the status menu.
Error code display:
999 Error in Errorlist
Error code status menu:
999 Error in Errorlist
Error handling:
Move on in the error list or leave the submenu “Error”.
Valve:
Valve is closed
Error Messages
154
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
11.3 Status Messages
The following table lists all the status messages you could encounter when using this system (see
Tab. 32). Status messages can appear while you plug IN or OUT a heater or a cooling valve, as well
as in connection with the calibration of a heater (see paragraph 7.13.2, page 77).
INFORMATION
Status messages are not stored
Status messages disappear after approx. 2 s from the display. They are not saved. A special case is
a calibration gone wrong. Then you get three times in a row the alternating messages “Wrong
calibration” and “Please try again!”, separated by approx. 1.5 s.
Status message Concerns Notes
Cooler connected
Cooling
Cooling valve connected successfully
Cooler could not be activated
Cooling
Cooling valve could not be activated (e.g. because the
flow control valve is not connected correctly or because
the wrong device is connected)
Cooler is disconnected
Cooling
Cooling valve was disconnected during operation
Heater connected
Heater
Heater connected successfully
Heater could not be activated
Heater
Heater could not be activated (e.g. because the heater
is not connected correctly or because the wrong device
is connected)
Heater is disconnected
Heater
Heater was disconnected during operation
Please try again!
Calibration
Calibration was not finished successfully (e.g. because
calibrator was connected twice). Please try again.
Wrong calibration
Calibration
Calibration of the heater (or of heater
and
cooling) not
correct
Tab. 32: List of status messages
Transport, Storage and Disposal
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
155
12 Transport, Storage and Disposal
12.1 Transport
For shipment, the system is packed in an appropriate case. Preserve it for further transport
procedures in the future. The necessity can never be excluded, e.g. for purposes of maintenance.
Observe the following measures.
If the original packaging is no longer available, select a suitable material for the package.
Pack in a way that protects the delivery against shock and vibrations.
Fill empty spaces with appropriate material (e.g. paper, insulating air cushion, Styrofoam).
Decontaminate the system completely before shipping it.
Fill out the corresponding form completely (see Page 174). Attach it, clearly visible, at the
exterior of the package.
CAUTION
Decontamination
The customer is liable for all consequences resulting from insufficient decontamination of the
system (health of transport personnel)!
12.2 Storage
The environmental conditions in the room intended for storage should fulfill the requirements of
the system.
Observe the following storage conditions.
The room should be sufficiently ventilated and free of dust
Admissible temperature: Between +5 °C and +30 °C
Rel. humidity < 50 %
The system should not be stored together with fuel, solvents, lubricants, acids and other
chemicals able to develop vapors, which may aggress to the surface of the components.
Air-tight foil sheathing with included desiccants may be useful.
12.3 Recycling and Disposal
The entire packaging consists of 100 % recyclable material.
At the end of its lifetime, the product itself should be discarded in conformity
with local regulations. Prescriptions with respect to handling of electrical
scrap have to be observed.