Vermes MDS 358X user Manual.pdf - 第108页
Communication Interfaces VTK - TR -BA- 072e - 1 - User Manua l MDS 358X S eries 97 35 SYSTEM:SHOW:ACTTEMP Descript ion: The cur rent temperat ure of the a ctua tor (pi ezo) is di splayed . NOTE: In case an MFC is connec …

Communication Interfaces
96
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
29 SYSTEM:KLOCK:OFF (KLOCK = Key Lock)
Description:
Access to keypad is permitted, the locking function disabled.
Example:
Input:
SYSTEM:KLOCK:OFF
Result:
The keypad of the control unit can be used.
Return:
OK
30 SYSTEM:KLOCK:ON (KLOCK = Key Lock)
Description:
This command locks the keypad of the control unit. This way, unauthorized
modification of parameters can be prevented.
Example:
Input:
SYSTEM:KLOCK:ON
Result:
The keypad is locked.
Return:
OK
31 SYSTEM:SHOW:CYCLES
Description:
The current value of the cycle counter is indicated.
Example:
Input:
SYSTEM:SHOW:CYCLES
Result:
Current value of the cycle counter.
Return:
1235000
32 SYSTEM:SHOW:VALVEID
Description:
The valve ID is displayed.
In case the system is in auxiliary mode, the return is “Auxiliary Mode”.
Example:
Input:
SYSTEM:SHOW:VALVEID
Result:
ID of the connected valve.
Return:
Valve ID: 10PEA001
33 SYSTEM:SHOW:CONTROLLERID
Description:
The ID of the control unit is displayed.
Example:
Input:
SYSTEM:SHOW:CONTROLLERID
Result:
ID of the control unit.
Return:
Controller ID: 13050
34 SYSTEM:SHOW:STATUS
Description:
This command sends the current status of KeyLock, DosOK with Delay,
SingleDosOK and Auxiliary Mode.
Example:
Input:
SYSTEM:SHOW:STATUS
Result:
Settings of the above listed items
Return:
KeyLock: OFF
DosOK with Delay: OFF
SingleDosOK: per pulse
Auxiliary Mode: OFF

Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
97
35 SYSTEM:SHOW:ACTTEMP
Description:
The current temperature of the actuator (piezo) is displayed.
NOTE:
In case an MFC is connected to your MDC, you cannot use this command,
since it would respond with a wrong value.
Example:
Input:
SYSTEM:SHOW:ACTTEMP
Result:
The value appears in °C.
Return:
70
36 SYSTEM:DOSOKDELAY:OFF
Description:
This command deactivates the DOSOK-Delay.
When this is true, the length of a delay is not added to the length of the
DOSOK signal.
Example:
Input:
SYSTEM:DOSOKDELAY:OFF
Result:
Deactivates the DOSOK-delay.
Return:
OK
37 SYSTEM:DOSOKAYDELAY:ON
Description:
This command activates the DOSOK-Delay.
When this is true, the length of a delay is added to the length of the DOSOK
signal.
Example:
Input:
SYSTEM:DOSOKDELAY:ON
Result:
Activates the DOSOK-delay.
Return:
OK
38 SYSTEM:SINGLEDOSOK:SETUP
Description:
This command sets the Single-DOSOK signal to “Setup”. The length of the
Single-DOSOK signal is that of the setup. (Default setting is “Pulse”.)
Example:
Input:
SYSTEM:SINGLEDOSOK:SETUP
Result:
The Single-DOSOK is set to “setup”.
Return:
OK
39 SYSTEM:SINGLEDOSOK:PULSE
Description:
This command sets the Single-DOSOK signal to “Pulse”. The length of the
Single-DOSOK signal is that of a pulse. (Default setting is “Pulse”.)
Example:
Input:
SYSTEM:SINGLEDOSOK:PULSE
Result:
The Single-DOSOK is set to “pulse”.
Return:
OK

Communication Interfaces
98
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
40 SYSTEM:PASSWORD:<Your password>
Description:
This command sends the 6-digit password to unlock the keypad after a
PLC-trigger. Each digit can be either of 1, 2, 3 or 4 (representing the keys
“[←]”, “[↑]”, “[↓]” and “[→]” resp.)
Example:
Input:
SYSTEM:PASSWORD:111111
Result:
The keypad is unlocked.
Return:
OK
41 SYSTEM:PASSWORD:OFF
Description:
This command deactivates the password, which unlocks the keypad after a
PLC-trigger.
Example:
Input:
SYSTEM:PASSWORD:OFF
Result:
The password is deactivated.
Return:
OK
42 SYSTEM:PASSWORD:ON
Description:
This command activates the password, which unlocks the keypad after a
PLC-trigger.
Example:
Input:
SYSTEM:PASSWORD:ON
Result:
The password is activated.
Return:
OK
43 SYSTEM:PASSWORD:SET:<Your password>
Description:
This command sets the 6-digit password, which can unlock the keypad
after a PLC-trigger. The password is 6-digit, with each digit either of 1, 2, 3
or 4 (representing the keys “[←]”, “[↑]”, “[↓]” and “[→]” resp.).
The password has to be exactly six digits long; anything else would lead to
an error.
Example:
Input:
SYSTEM:PASSWORD:SET:111111
Result:
The 6-digit password is set.
Return:
OK
44 SYSTEM:AUXILIARYMODE:OFF
Description:
This command deactivates the auxiliary mode.
In auxiliary mode, the valve is disconnected. All other functionalities of the
MDC can be used and tested.
Example:
Input:
SYSTEM:AUXILIARYMODE:OFF
Result:
The auxiliary mode is deactivated.
Return:
OK
45 SYSTEM:AUXILIARYMODE:ON
Description:
This command activates the auxiliary mode.
In auxiliary mode, the valve is disconnected. All other functionalities of the
MDC can be used and tested.
Example:
Input:
SYSTEM:AUXILIARYMODE:ON
Result:
The auxiliary mode is activated.
Return:
OK