2.1.1 Technical Data.
Component Camera, Stationary, P&P (Type 33) 55x45
Component dimensions 0.5 mm x 0.5 mm to 55 mm x 45 mm for single measurement of
component
Component spectrum 0402, MELF, SO, PLCC, QFP, electrolytic capacitors, BGA
Min. lead pitch 0.30 mm
Min. lead width 0.15 mm
Min. ball pitch 0.35 mm
Min. ball diameter 0.20 mm
Field of view 65 x 50 mm
2
Method of illumination Front-lighting (6 levels, programmable as required)
Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
Component dimensions 0.2 mm x 0.2 mm to 16 mm x 16 mm for single measurement of
component
Component spectrum 0402 to SO, PLCC, QFP, sockets, plugs, BGA, special components,
bare dies, flip-chips, shields
Min. lead pitch 0.25 mm
Min. lead width 0.1 mm
Min. ball pitch 0.14 mm
Min. ball diameter 0.08 mm
Field of view 19.4 x 19.4 mm
Method of illumination Front-lighting (6 levels, programmable as required)
2.1.2 Version Overview
Version
SST33
Description
01, 02 Not available for these machines
03 to 06 With CAN controller (as TQ module), VCU not required, 8 pin DIP switch on the driver
board
From 06 Simpler assembly with key holes
From 07 With CAN controller (integrated on the board), VCU not required, 6 pin DIP switch on
the driver board
Version
SST25
Description
01 Not available for these machines
From 03 Depending on the type series, the camera either has an 8 pin or 6 pin DIP switch in it.
The CAN controller is located directly on the driver board.
From 05 With CAN controller (integrated on the board), VCU not required. Version 03 and 05
have the same design. Multiplexer integrated on the board.
2 Brief Description
2.2 Overview of X Series S Machines
Assembly Instructions / Montageanleitung SIPLACE X-Series S Stationary Camera Type 25/33 Stationäre Kamera
Typ 25/33 06/2016
71
2.2 Overview of X Series S Machines
Machine overview (example of X3 S, X4 S shown)
1. Location 1
2. Location 2
3. Location 3
4. Location 4
5. GCU, BoxPC, I/O modules
6. Power Supply
2.3 Requirements
Machines with only C&P20A heads will only have one hotlink card fitted. When converting to a CPP
or TwinHead, you need to install an additional "hotlink interface PCI-A24-K01" [03052135Sxx] in
the Box PC.
2.4 Configurations
The following stationary camera configurations can be fitted at the locations of X3 S, X4 S and
X4i S machines, with the exception of PA1:
Location Configuration
1 IC camera, type 33
2 IC camera, type 33
IC camera type 33 and FC camera type 25
3 IC camera, type 33
IC camera type 33 and FC camera type 25
4 IC camera, type 33
2 Brief Description
2.5 Scope of Delivery
72 Assembly Instructions / Montageanleitung SIPLACE X-Series S Stationary Camera Type 25/33 Stationäre Kamera
Typ 25/33 06/2016
2.5 Scope of Delivery
Component camera, stationary P&P (type 33) 55x45 [00519893Sxx]
Quantity Designation Item No.
1 Component camera, stationary P+P (type 33) 55x45 digital 03016339-xx
1 Assy holder calibr. jig repository LOC4 03098073-xx
1 IC camera adaptor assembly LOC4 SX4a 03099004-xx
1 Waste box TwinHead PA1 SX4a assembly 03097354-xx
1 IC camera adaptor assembly 03099054-xx
1 Connecting sheet assembly 03097430-xx
1 Cable: reject bin sensors 03090846-xx
1 Option parts reject bin 03090847-xx
1 Retaining plate assembly for reject bin assembly 03094709-xx
1 Patch cable Cat6 600MHz 2xRJ45 3m OG 03039067-xx
Stationary P&P component camera, type 25 16 x 16, digital (FC camera) [00519829-xx]
Count Description Item No.
1 Component camera, stationary P+P (type 25) 16x16 digit. 03020578-
1 IC camera adaptor assembly SX4 03080926-
1 Retro. man. Flip-Chip camera 16x16, X-Series 00194554-
2 DIN 913 - M 6 x 50-ST 03005958-
1 Cable: extension camera bus IC/FC camera 03055279-
1 Cable: extension power FC camera 03055298-
1 CAN bus: IC camera 03050239-
1 Support plate FC 03077911-
2.6 Tools and Equipment Required
ESD tape
Shelf for lighting unit
Set of Allen keys
Set of screwdrivers
Universal pliers
Long Allen key with T-handle (at least 30 cm) size 6
Cable ties
Microfiber cloth for cleaning optical assemblies
Assembly Instructions "SIPLACE X-Series S, stationary camera type 25/33" [DE+EN:
00197397-xx]
If necessary: Assembly instructions "Row 2 Nozzle Changer – Nozzle Changer Before
MTC" [DE+EN:00197369‑xx]
Service manual "SIPLACE X-Series S" [DE: 00197041-xx] [EN: 00197042-xx]
2.7 Required Working Time
The complete installation will take approx. between 1 and 2 hours. The work time depends primar-