2500_Users_Manual.pdf - 第420页
Local Mo de F-8 Pro Mast er 25 00 Use r Man ual Type a filename no t currently on the lis t of files or use the arrow keys to scroll to files not listed on the disp lay. ( Only eight fil enames appear o n the screen at o…

Local Mode
ProMaster 2500 User Manual F-7
Editing an Existing File
To select a file, scroll to that filename and press
ENTER
, or type the name
of a file and press
ENTER
. The filename is shown on the top line of the
display:
To change the device package, press
Y
. Otherwise, press
N
or
ENTER
.
The 2500 displays:
Press
Y
to select a new font. Otherwise, press
N
. The 2500 asks you to
select the orientation of pin 1 in the tracks. When the text file is ready to
be edited, the 2500 displays:
Up to three lines of text with 25 characters per line are available, but the
number of lines and characters that you can put on a device is limited by
the size of the device, the label, and type. Enter the text you want on the
label. Existing text is overwritten.
To delete a character, move the cursor one space to the right of the
character you want to delete, and press
DEL
. To insert a space between
two characters, move the cursor to the right of where you want to add a
space, and press
SHIFT
and
SPACE
at the same time.
When editing is complete, press
STOP
. The 2500 displays:
If you do not wish to save the file, press
N
or
RESET
. If you wish to save
it, press
Y
. Then press any key to return to the File Utilities Menu.
Create a New File
To create a new file, press
1
from the File Utilities menu. The 2500
displays:
FILE EDIT MODE FILENAME: FILE5
CURRENT PART IS: CUSTOM LENGTH: .250
DO YOU WISH TO CHANGE? (Y OR N):
FILE EDIT MODE FILENAME: FILE5
CURRENT FONT IS: xxxx LENGTH: .250
DO YOU WISH TO CHANGE? (Y OR N):
ABCDEFGHI |FILE NAME: FILE5
JKLMNOPQR |COLUMN X ROW X
123456789 |PRESS STOP WHEN
|EDITING IS COMPLETE
U43 |FILE NAME: FILE5
DATA I/O CORP |COLUMN X ROW X
VER 2.1 1993 |DO YOU WANT TO SAVE
|THIS FILE? (Y OR N)
FILE EDIT MODE
FILE1 FILE2 FILE3 FILE4
FILE5 FILE6 FILE7 FILE8
ENTER FILE NAME TO EDIT:

Local Mode
F-8 ProMaster 2500 User Manual
Type a filename not currently on the list of files or use the arrow keys to
scroll to files not listed on the display. (Only eight filenames appear on
the screen at one time.)
The 2500 creates the new file and displays:
Since this is a new file, no default values are shown. Enter the device and
text information as described in the section called “Creating the
Temporary File” earlier in this chapter. Press any key (except
RESET
) to
return to the File Utilities Menu.
Delete Files
To select DELETE FILES, press
2
from the File Utilities Menu. The 2500
displays:
Type the name of the file to delete, or scroll to the name and press
ENTER
. The 2500 displays:
Press
Y
to delete the file and the 2500 displays:
Press
Y
to delete another file or press any other key. The 2500 displays:
Press any key other than
Y
to return to the File Utilities Menu.
To return to the Main Menu, press
RESET
or press
3
from the File
Utilities Menu.
FILE EDIT MODE
FILE1 FILE2 FILE3 FILE4
FILE5 FILE6 FILE7 FILE8
ENTER FILE NAME TO EDIT: NEWNAME
FILE EDIT MODE NEW FILE: NEWNAME
CUSTOM PLCC 20 PLCC 28 PLCC 32
PLCC 44 PLCC 52 PLCC 68 PLCC 84
MOVE TO SELECTION THEN PRESS ENTER
FILE DELETE MODE
FILE1 FILE2 FILE3 FILE4
FILE5 FILE6 FILE7 FILE8
ENTER FILE NAME TO DELETE:
FILE DELETE MODE FILE NAME: NEWNAME
DELETE THIS FILE? (Y OR N)
FILE DELETE MODE FILE NAME: NEWNAME
DELETE THIS FILE? (Y OR N) Y
FILE WAS DELETED, DELETE ANOTHER FILE?
FILE DELETE MODE FILE NAME: NEWNAME
DELETE THIS FILE? (Y OR N) N
FILE NOT DELETED, DELETE ANOTHER FILE?

Local Mode
ProMaster 2500 User Manual F-9
System Setup Menu
There are three submenus under System Setup.
General Setup Menu
General setup allows you to change the port settings and choose to turn
the audible alarm on or off. The access these from the 2500 Main Menu,
press
3
to select SYSTEM SETUP.
The 2500 displays:
Press
1
to select the GENERAL SETUP MENU.
Audible Alarm
If the Audible Alarm is enabled, a tone is emitted for every keystroke and
error message. To enable or disable the Audible Alarm, press
1
from the
General Setup Menu. If the alarm is currently enabled, the 2500 displays:
If it is disabled, ON appears instead of OFF. Press
Y
if you wish to toggle
to the other state.
Remote and
Programmer Baud
Rates
To change the baud rate on the Remote Port, press
2
. The 2500 displays:
Press the number corresponding to the baud rate you want to use.
Change the baud rate on the Programmer Port in the same way by
pressing
3
. The 2500 displays:
Select the number next to the baud rate you want to use.
To return to the Main Menu, press
RESET
.
* * PROMASTER 2500 MAIN MENU * *
ENTER THE NUMBER OF THE DESIRED FUNCTION
1 - OPERATIONS 3 - SYSTEM SETUP
2 - FILE UTILITIES 4 - DIAGNOSTICS
* * * SYSTEM SETUP MENU * * *
1 - GENERAL 4 - MAIN MENU
2 - LABELER
3 - HANDLER
* * * GENERAL SETUP MENU * * *
1 - AUDIBLE ALARM 4 - SETUP MENU
2 - REMOTE BAUD RATE
3 - PROGRAMMER BAUD RATE
DO YOU WANT AUDIBLE ALARM OFF?
(Y OR N):
ENTER NUMBER OF REMOTE BAUD RATE
DESIRED (X):
1 - 1200 2 - 2400 3 - 4800 4 - 9600
5 - 19200 6 - 38400
ENTER NUMBER OF PROGRAMMER BAUD RATE
DESIRED (X):
1 - 1200 2 - 2400 3 - 4800 4 - 9600
5 - 19200 6 - 38400