Insta llatio n and Se tup 2-24 ProMa ster 25 00 U ser Ma nual 2. Pr ess 2 to select LABELER. The 2500 dis plays this menu: Label Calibration Label calibration determines the dista nce between the edge of the label and th…

100%1 / 448
Installation and Setup
ProMaster 2500 User Manual 2-23
4. With the cursor pointing to the Temporary file, press
ENTER
to select
it. The 2500 displays:
Use the
,
,
,
to point to one of the fonts.
5. Press
ENTER
to select that font. The 2500 displays:
6. Use the keyboard to enter label text. Press
STOP
when text entry is
complete. The 2500 displays:
7. Position your finger near the label platen so you are ready to “catch”
the label as it is printed. Press
START
to print a label. Each time you
press
START
another label is printed.
8. When you are finished, press
RESET
to return to the Main Menu.
Labeler Setup Menu
Follow the procedures below to set up label calibration, label placement,
and label adjust. The 2500 must be in local mode to access these
commands.
1. Press
3
from the 2500 Main Menu. The 2500 displays:
PRINT LABEL TEMPORARY FILE
AUTO-SEL 26 CPI 26 CPI S 20 CPI
18 CPI 16 CPI T 12 CPI T
MOVE TO SELECTION THEN PRESS ENTER
TTTT | TEMPORARY FILE
HHHH | COLUMN: 01 ROW: 01
| PRESS STOP WHEN
| EDITING IS COMPLETE
PRINT LABEL FILE NAME: FILE5
PRESS START TO PRINT
A LABEL
Figure 2-14
Labeler Setup Path (Local mode on
the front panel)
* * * SYSTEM SETUP MENU * * *
1 - GENERAL 4 - MAIN MENU
2 - LABELER
3 - HANDLER
SYSTEM
SETUP
Label Calibration
Label Placement
Label Adjust
Print Mode
Label Type
Setup Menu
DIAGNOSTICS
MAIN MENU
HANDLER
GENERAL
FILE
UTILITIES
OPERATIONS
1343-4
LABELER
Installation and Setup
2-24 ProMaster 2500 User Manual
2. Press
2
to select LABELER. The 2500 displays this menu:
Label Calibration
Label calibration determines the distance between the edge of the label
and the first printed character. This value is set at the factory and does not
usually need to be changed. If the text is not being printed on the label in
the proper location, ensure that the following conditions have been met:
Labels have been calibrated.
Labeler’s pinch rollers are fully engaged against the drive roller.
ADC value is correctly set to 200 (see page 5-34 for this procedure).
Correct labels for the 2500 (“QF” in the part number) are installed.
If these actions do not resolve the placement problem, you may need to
adjust label calibration.
To change the current label calibration value from the 2500’s front panel,
put the 2500 in local mode. The 2500 displays:
Press
1
from the LABELER SETUP MENU. The 2500 displays:
Use the 2500’s keyboard to change the setting. The range is from 0 to 255.
After entering the desired value, save it by pressing the
ENTER
key. The
2500 records this value as the new default and returns to the LABELER
SETUP MENU.
Note: If you change the label calibration value, press
CAL
so that the ADC optic
performs the ADC optic label calibration (see page 2-11).
* * * LABELER SETUP MENU * * *
1 - LABEL CALIBRATION 4 - SETUP MENU
2 - LABEL PLACEMENT
3 - LABEL ADJUST
Figure 2-15
Changing the Label Calibration
Value
* * * LABELER SETUP MENU * * *
1 - LABEL CALIBRATION 4 - SETUP MENU
2 - LABEL PLACEMENT
3 - LABEL ADJUST
ENTER LABEL CALIBRATION VALUE (XX):_
1944-1
NORMAL
HIGHER VALUE
Installation and Setup
ProMaster 2500 User Manual 2-25
The label calibration value can also be changed while the 2500 is
processing devices using the STOP command. Press
STOP
on the 2500’s
keyboard and then
LOWER CASE
+
C
. The 2500 displays:
where X represents the current setting. Enter a new value (between 0 and
255) on the 2500’s keyboard. Press
ENTER
to save the value.
Press
CAL
to run the ADC optic’s label calibration. When the calibration
has completed, press
START
to continue running the Task.
Label Placement
The label placement value controls the position of the label on the device.
Using the factory default setting (autocenter), the 2500 positions the label
in the center of the device.
You can change this parameter either from the 2500’s front panel or in
TaskLink. To change the value in TaskLink, refer to the
ProMaster
dialog
box on page 3-9.
To change the label placement from the 2500’s front panel, press
2
from
the LABELER SETUP MENU.
The 2500 displays:
where X represents the current setting. Enter a number from 0 to 254 to
change the setting. Entering 0 places the left end of the label on the
leading edge of the device. Each increase in this value moves the label
0.010 inch further away (delayed) from the leading edge of the device.
After entering the value, press
ENTER
to save the new setting.
PROGRAM/TEST LABEL
ENTER LABEL CALIBRATION VALUE (X):_
* * * LABELER SETUP MENU * * *
1 - LABEL CALIBRATION 4 - SETUP MENU
2 - LABEL PLACEMENT
3 - LABEL ADJUST
ENTER LABEL PLACEMENT VALUE (X):_
ENTER “A” FOR AUTO CENTERING
Figure 2-16
Changing the Label Placement
Value
PLACEMENT = 0
PLACEMENT = A
1363-2
LABELLABEL