M20_Ope_E.pdf - 第321页
Chapter 10 Replenishing Com ponents and Using Maintenance Menus 10-17 10-4-5 Actuators Actuators mean devices to cause a machine to functi on. In this system, actuators specifically mean pneumatic-driven devices and part…

Chapter 10 Replenishing Components and Using Maintenance Menus
10-16
10-4-3 Serial I/O
■ Serial I/O List
Serial signal output (Device 1・3・5・7・9・11・13・15)
Serial signal input (Device 2・4・6・8・10・12・14・16)
Action:
① Click the [Status] cell of the actuator you want to operate.
② At the same time you click the cell, the display changes 1(On) or 0(Off), and the actuator
moves accordingly.
Example:
■ Moving Up and Down the Board Stopper
① Select Manual> Signal I/O to open the [Serial I/O] window.
② Select the [Device1] tab.
③ Click the [Status] cell of [Board Stopper Up A]. The status changes “0” to “1” and the board
stopper moves up. At this time, confirm that the [Status] cell of [Board Stopper Up A] in
[Device2] switches from “0” to “1”.
④ To move down the board stopper, click the [Status] cell of [Board Stopper Up A] in
[Device1] again. The status changes “1” to “0”. At the same time, the [Status] cell of [Board
Stopper Up A] in [Device2] switches from “1” to “0”.
Turning on/off signal output in the Signal Output (Control) window allows an actuator
to move. During this operation, do not stick your head, hands, or other parts of the body
inside the mounter or tray feeder. Serious injury can result. Also make sure
non-operators are a safe distance from the mounter or tray feeder.
During signal output on/off operation, make sure no foreign obstacles are left in the mounter or
tray feeder. Otherwise, costly machine damage can occur.
10-4-4 Signal Input/Output Map
For the signal input/output map (signal input/output list), refer to the M10M20 service manual,
Chapter 4 “Electrical Section” > Signal Output Map/Signal Input Map.
Warning
Caution

Chapter 10 Replenishing Components and Using Maintenance Menus
10-17
10-4-5 Actuators
Actuators mean devices to cause a machine to function. In this system, actuators specifically
mean pneumatic-driven devices and parts feeders. The Actuator menu allows you to check
each actuator movement and to measure its timing.
The Actuator allows the specified actuator to move. While operating actuators via this
menu, do not stick your head, hands, or other physical parts inside the mounter or the
tray feeder. Serious injury may result. Also make sure non-operator are at a safe
distance from the mounter or the tray feeder.
Before operating actuators, make sure no foreign obstacles are left in the mounter and the tray
feeder. The mounter and the tray feeder may cause damage.
Menu: Manual>Actuator
On/Off tab
* The number of heads differs depending on the mounter model.
Action:
① Under [Select Actuator], select a type of actuator.
② Click <OFF> button for the desired actuator. <OFF> button turns to <ON> and the
actuator starts to operate.
③ Click <ON> button. <ON> button turns to <OFF> and the actuator stops to operate.
Window:
Head Vacuum Head1 Vacuum
Head2 Vacuum
Head3 Vacuum
Head4 Vacuum
Head5 Vacuum
Head6 Vacuum
Warning
Caution
Chapter 10 Replenishing Components and Using Maintenance Menus
10-18
Board Clamp Board stopper ON
Second stopper UP
Quick clamp UP
Push-up plate
Head Vacuum Breaker Head1 Vacuum Breaker
Head2 Vacuum Breaker
Head3 Vacuum Breaker
Head4 Vacuum Breaker
Head5 Vacuum Breaker
Head6 Vacuum Breaker
ANC ANC Open