M20_Ope_E.pdf - 第455页
1619 Teaching ends. 1620 Manual ends. 1621 Origin detection ends. 1573 PCB Vacuum Error. Check PCB Vacuum for error. 1574 MX-20 Relay Hook Retract End Sensor Off (Pallet- Check conditions of MX-20. 1575 %d1) Start %s (%d…

%d1 return MX-20 to origin.
1572
MX-20 Pallet detect sensor in Stocker is OFF.
Pallet-%d1
Insert the specified Pallet into MX-20 stocker.
1534 %s Pallet detect sensor on hook ON. (Pallet-%d2) Check conditions of MXR
1535 %s Pallet detect sensor on hook OFF. (Pallet-%d2) Check conditions of MXR
1536 %s Pallet side clamp sensor ON. (Pallet-%d2) Check conditions of MXR
1537 %s Pallet side clamp sensor OFF. (Pallet-%d2) Check conditions of MXR
1538 %s Pallet rear clamp sensor ON. (Pallet-%d2) Check conditions of MXR
1539
1540
%s Pallet rear clamp sensor OFF. (Pallet-%d2)
%s Hook-axis is out of origin position. (Pallet-%d2)
Check conditions of MXR
Check conditions of MXR
1541
1542
%s Hook-axis is out of supply position. (Pallet-%d2)
%s Failed in Assigning Elevator Moving Position
Check conditions of MXR
Check conditions of MXR
(Pallet-%d2)
1543
%s Failed in Assigning Hook Moving Position (Pallet-
Check conditions of MXR
1544
1545
%d2)
%s Door Open (Pallet-%d2)
%s Elevator Slow-down Stop (Pallet-%d2)
Check conditions of MXR
Check conditions of MXR
1546
%s Pallet Interlock. Remove the pallet in the middle of
being supplied and check in the Manual menu. Then Check conditions of MXR
1547
perform axis zeroing.
The relay hook of MX20 is not in Stocker Position for
Secure the safety of MX20 unit and take origin.
Relay" position."
1548
No PCB has been selected in the PCB select bad
mark" process."
Check the board for bad marks.
1549 Nozzle No.[%d2] is not found in nozzle library. Check nozzle library.
1550 Cannot perform dispense check.
Check the image library and the image code in the
1551 Cannot capture an image in dispense check.
dispense library.
Process is not properly performed. Contact us.
1552
1553
Syringe change signal for Head%c1 has been
The nozzle set in the dedicated ANC is different from
Acception parameter for syringe has been initialized.
Check nozzle setting.
1554
specified one. ANC(%d1)
Nozzle is set on the Head%c1.
Check ANC shutter and missetting of nozzle. Contact
us for ANC scanning error.
1555
1556
Communication fails.
System status is changed.
Cancel command cannot be sent to the vision
system. Contact us.
System diagnoses itself.
1557
Head%s Dispense Correction OK count:%p2 Average
ratio:%d3% Tolerance:%d4%-%d5% Correction
Value:%v8Mpa Pressure:%v6Mpa Retry Count:%d7 %m
Executing Dispense Correction
1558
Head%s Dispense Check OK OK count:%p2 Average
ratio:%d3% Tolerance:%d4%-%d5% Pressure:%v6Mpa
Correction coefficient:%v1 Retry Count:%d7 %m
Dispense Check Passed
1559
Short of nozzles for the current program. Nozzle:%d1
Number of Nozzles:%d2 Number of set nozzles:%d3
Number of shortage nozzles:%d4 %s
Set the required nozzles.
1560
Shortage of the optimum number of nozzles.
Nozzle:%d1 Optimum number:%d2 Set number:%d3
Set the proper number of nozzles for efficient
production.
1561
Short number:%d4 %s
Automatic nozzle arrangement will be skipped
Check the setting in User Parameter > Functions.
1562
according to the user parameter setting.
Auto nozzle arrangement cannot be performed
Release the Fixed Nozzle setting for head 1 and 2.
because head 1 and/or 2 are set for Fixed Nozzle"."
1563
Component %m" is not set on %s-%d1. Feeder ID
%d2-%d3"
Confirm the component on the feeder.
1564
1565
The program cannot be run since feeder is
Exceeded the maximum correction value. %s(X:%d1
Y:%d2 T:%d3) Head%c4 %m
Confirm the feeder location.
Click the <LOG> button to obtain Log data, and
contact us.
1566
Remove the pallet-%d1 from the tray feeder. It must
be done while the Servo motor is off.
Turn off the Servo motor from the Maintenance
Menu. Remove the pallet, which was failed to be
1567
The nozzles required for the production are not set at
delivered, out of the tray feeder and return all the
Set the nozzle at proper position where the head can
1568
proper position of ANC. Head%c1 Nozzle:%d2
Z-axis did not reach the pickup height when pickup.
use.
Check the Head Z axis condition.
1569
Head%c1 Nozzle:%d2
Z-axis did not reach the placement height when
Check the Head Z axis condition.
1570
placement. Head%c1 Nozzle:%d2
Z-axis did not reach the Reject/Return height when
Check the Head Z axis condition.
1571
Reject/Return Component. Head%c1 Nozzle:%d2
MX-20 Pallet detect sensor in Stocker is ON. Pallet- Remove the specified Pallet from MX-20 stocker and

1619 Teaching ends.
1620 Manual ends.
1621 Origin detection ends.
1573 PCB Vacuum Error. Check PCB Vacuum for error.
1574
MX-20 Relay Hook Retract End Sensor Off (Pallet-
Check conditions of MX-20.
1575
%d1)
Start %s (%d1,%d2,%d3,%d4,%d5,%d6,%d7,%d8)
1576 End %s (Total:%d1 NG:%d2 Time:%d3.%d4sec)
1577
Error is detected on %s-%d1(Count:%d1 NG
Count:%d2Code:%d3 ID:%d4-%d5)
1578
1579
Skip %s %d1 times.(NG:%d2 Time:%d3.%d4sec)
Communication error happened between Mounter
Check the ID Database Server and LAN condition.
1580
and Feeder ID Database.(%d1<%d2msec)
Feeder position error. %s-%d1 -> %c4-%d5 %m" Feeder set position is wrong. Relocate it to the
1581
ID:%d2-%d3"
Feeder position error. %s-%d1 -> %c4-%d5 %m"
specified.
Feeder set position is wrong. Relocate it to the
ID:%d2-%d3" specified.
1582 Set position: %s-%d <- %m""
Remove the feeder from the specified station and set
the component.
1583
1584
Set position: %s-%d <- %m""
Component %m" has already been set."
Set the component to the specified station.
This component has already been set.
1585
1586
Component %m" is not used for this production."
Lead/Ball Height deviation is out of tolerance.
This component is not used for this production.
Check Lead/Ball floating condition and Lead/Ball
1587
Head%c1 %m
Lead/Ball Position XY deviation is out of tolerance.
Height Tolerance value.
Check Lead/Ball bending condition and Lead/Ball
1588
Head%c1 %m
No Lead/Ball-like object is found in measuring image.
pos. XY Tolerance value.
Check component data/thickness/condition.
1589
Head%c1 %m
Component image is out of measuring image range.
Check component data/thickness/condition.
1590
Head%c1 %m
Measured position of Lead/Ball markedly differs from
the setting of component data. Head%c1 %m
Check component data/thickness/condition.
1591
Lead/Ball is missing at predetermined location.
Head%c1 %m
Check Lead/Ball condition and settings of Component
Feature, Darkness level, Lead/Ball Pitch, and
1592
Tilt amount of Reference Surface is out of tolerance.
Lead/Ball Width in Coplanarity Check data.
Check component tilt condition and value of Tilt
1593
Head%c1 %m
Coplanarity Check Error occurred. Head%c1 %m
Tolerance of Ref. Surface in Coplanarity Check data.
Check component data/thickness/condition. Refer to
Error Code List for details.
1594 Fails to perform Coplanarity Check.
Check Coplanarity Check Unit and Communication
1595 Fails to capture the image at Coplanarity Check.
cables for any abnormal conditions.
Process is not properly performed. Contact us.
1596
1597
Fails to acquire the result at Coplanarity Check.
The head cannot reach a nozzle.
Process is not properly performed. Contact us.
Change a pickup head or the nozzle position. Or
enable the Automatic Nozzle Arrangement.
1598
Exceeded the maximum correction value. %s(X:%d1 Check that the maximum correction value is set
Y:%d2 T:%d3) Head%c4 %m properly.
1599 Improper component feeding %s #%d1 Head%c2 Stop operation and check feeding conditions.
1600 Processing ends. (servo motor off)
1601 Edition in pause.
1602 Teaching is possible. Perform operation safely. Each axis operates in safety speed.
1603 Manual is possible. Perform operation safely. Caution: Z axis does not move in safe height.
1604 Ready (Alarm off and recovery possible)
1605 Pause (Cancel or start possible)
1606 Run (Press cycle stop for stop and cancel for end)
1607
1608
Drive OFF
Maintenance possible.
Drive ON possible
Servo off for operation
1609 Alarm of servo/DC motor %s Check servo unit.
1610 Servo of caused by emergency stop
Emergency stop is pressed. System detects trouble
automatically.
1611 Wait until origins are taken. Each axis is taking its origin.
1612 Wait until movement ends.
Axis moves to specified coordinates. Press
emergency stop switch to stop movement.
1613 Load board
1614 starting signal is accepted. Data for run is collected.
1615 Run-starting-signal is accepted. Data for run is collected.
1616 Quit the system. Power is automatically turned off.
1617 Performance record is collected. Performance record is written on management data
1618 is saved. Data is saved on file. Use to prevent mis-saving.

1709 Specified illumination level is set.
1710 Model data is acquired. Model data is stored in file.
1711 Model centering Center of F mark is detected, where camera moves.
1622 PCB through ends.
1623 Run ends.
1624 starts.
1625 ends.
1626 ended without completing the job.
1627 MMI MSG
1628 MMI MSG
1629 Job run ended without completing the job.
1630 Job run ended without completing the job.
1631 Start warm-up
1632 End warm-up
1633 Start warm-up for the specified item.
1634 End warm-up for the specified item.
1635 Producible PCB count has reached the alarm setting. Replenish components.
1636
1637 Pause the current job and enter Edit&Teach mode.
(clear signal tower of 1635)
1638 Exit Edit&Teach mode and resume the current job.
Contact failure of CPU and CPU controller board.
1639 Failed to load the controller program. [%d1]
Check the contact of each board.
1640
1641
execute ends.
Instantaneous power failure is detected.
1642 Pause (Cancel or start possible)
The UPS does not operate normally. Contact i-
1643 The control board is not adapted to the system.
PULSE local distributor.
1644 Feeders setup are verified.
1650 Operational switch is pressed.
1651 System condition changes.
1656 System condition changes.
1659 Prearrange process starts.
1660 MX Info. starts.
1661 Nozzle ID recognition starts.
1662 Nozzle change starts.
1663 Prearrange process ends.
1664 MX Info. ends.
1665 Nozzle ID recognition ends.
1666 Nozzle change ends.
1667 Nozzle ID manual setting ends.
1668 Nozzle ID recognition ends without completing the
1669 Nozzle change ends without completing the job.
1670
1671
%c1 MMI MSG
%c1 MMI MSG
1672 Fiducial mark coordinates have been obtained.
Coordinates have been obtained without fiducial
1673
correction.
1680 User parameter is saved. Data is saved on file. Use to prevent mis-saving.
1681 System parameter is saved. Data is saved on file. Use to prevent mis-saving.
1682 Component library is saved. Data is saved on file. Use to prevent mis-saving.
1683 Image library is saved. Data is saved on file. Use to prevent mis-saving.
1684 Feeder library is saved. Data is saved on file. Use to prevent mis-saving.
1685 Pallet library is saved. Data is saved on file. Use to prevent mis-saving.
1686 Packaging library is saved. Data is saved on file. Use to prevent mis-saving.
1687 Tray library is saved. Data is saved on file. Use to prevent mis-saving.
1688 Nozzle library is saved. Data is saved on file. Use to prevent mis-saving.
1689 Dispense library is saved. Data is saved on file. Use to prevent mis-saving.
1690 Syringe library is saved. Data is saved on file. Use to prevent mis-saving.
1691 Dispense Nozzle library is saved. Data is saved on file. Use to prevent mis-saving.
1692 Production plan is updated. Data is saved on file. Use to prevent mis-saving.
1701 Camera change
1702 Image mode change
1703 Image test is performed. Image test is performed. Warning; any axis may move.
1704 Guide frame display command
1705
1706
Camera center cross line
ADA is performed. ADA(Automatic Data Acquisition) is performed.
1707 Multi-view image test result is displayed.
Component (except chip) size is automatically
1708 ADA is performed.
measured.