Chapter 16 Dispenser
16-30
After removing any residual dispense material from the ceramic nozzle interiors, wash
the nozzle ultrasonically in ethyl alcohol or isopropyl alcohol. Use care not to damage
the nozzle during the ultrasonic washing process.
In particular, do not wash nozzle together with other components. Doing so could
cause contact with the other components, possibly resulting in nozzle damage. Always
wash nozzles individually.
16-5-1-5 Reassembling the cartridge body
Action:
Insert the lower bearing and seal ring into the screw.
Note: While inserting the lower bearing and seal ring, grasp the hexagon top of the screw and turn the screw
gently in the counterclockwise direction.
Insert these two components one at a time. Do not attempt to insert them together.
After inserting the lower bearing and seal ring into the screw, insert the screw into the
cartridge body. Be sure that the lower bearing's V-cut is aligned with the cartridge
body's anti-rotation pin when inserting the screw into the cartridge body. This
alignment is facilitated by referring to the guide mark on the cartridge body.
Insert the upper bearing into the cartridge body and screw.
Ceramic nozzle
Screw
Seal ring
Lower bearing
Upper bearing
Screw with lower
bearing and seal
ring inserted
Cartridge body
Anti-rotation
pin
Guide mark
V-cut
Cartridge body
Lower bearing
Chapter 16 Dispenser
16-31
Attach and tighten the screw retainer cap.
Note: Finally, grasp the hexagon top of the screw and rotate the screw to verify that rotation occurs easily
without interference.
It may be impossible to rotate the screw if the screw retainer cap is tightened with the lower bearing and
upper bearings inserted incorrectly.
Attach the face seal to the adapter plate.
Turn the cartridge body upside down and attach the adapter plate.
In this posture, also attach the ceramic nozzle.
Note: From this point, use care to protect the ceramic nozzle from damage (prevent it from striking hard objects,
etc.).
Attach and tighten the nozzle retainer cap.
Adapter plate
Face seal
Chapter 16 Dispenser
16-32
16-5-2 Cleaning the tube joint
16-5-2-1 Removing the tube joint
Action:
Turn the syringe in the counterclockwise direction to remove it.
Loosen the tube joint nut at the cartridge body side, then disconnect the tube from the
cartridge body.
Remove the O-ring from inside the cartridge body joint.
Note: When removing the O-ring, use care to prevent it from making contact with sharp objects.
Such contact could damage the O-ring, making it unusable.
If the O-ring cannot be easily removed, use a piece of adhesive tape, etc., to remove it.
Remove the O-ring.
It can be easily extracted by using a
piece of adhesive tape, etc.
O-ring
Loosen this nut
Cartridge
body
Tube
Tube joint