Chapter 16 Dispenser
16-32
16-5-2 Cleaning the tube joint
16-5-2-1 Removing the tube joint
Action:
Turn the syringe in the counterclockwise direction to remove it.
Loosen the tube joint nut at the cartridge body side, then disconnect the tube from the
cartridge body.
Remove the O-ring from inside the cartridge body joint.
Note: When removing the O-ring, use care to prevent it from making contact with sharp objects.
Such contact could damage the O-ring, making it unusable.
If the O-ring cannot be easily removed, use a piece of adhesive tape, etc., to remove it.
Remove the O-ring.
It can be easily extracted by using a
piece of adhesive tape, etc.
O-ring
Loosen this nut
Cartridge
body
Tube
Tube joint
Chapter 16 Dispenser
16-33
16-5-2-2 Disassembling the tube joint
Action:
Loosen the tube clamp bolt at the cartridge body side.
Extract the tube clamp and tube from the tube joint.
Tube clamp
Loosen this bolt.
Tube
Tube joint
Cartridge body side
Chapter 16 Dispenser
16-34
Loosen the tube clamp bolt at the syringe side.
Extract the tube clamp and tube from the tube joint.
Tube clamp
Loosen this bolt.
Tube Tube joint
Syringe side