Chapter 16 Dispenser
16-32
16-5-2 Cleaning the tube joint
16-5-2-1 Removing the tube joint
Action:
① Turn the syringe in the counterclockwise direction to remove it.
② Loosen the tube joint nut at the cartridge body side, then disconnect the tube from the
cartridge body.
③ Remove the O-ring from inside the cartridge body joint.
Note: When removing the O-ring, use care to prevent it from making contact with sharp objects.
Such contact could damage the O-ring, making it unusable.
If the O-ring cannot be easily removed, use a piece of adhesive tape, etc., to remove it.
Remove the O-ring.
It can be easily extracted by using a
piece of adhesive tape, etc.
O-ring
Loosen this nut
Cartridge
body
Tube
Tube joint

Chapter 16 Dispenser
16-33
16-5-2-2 Disassembling the tube joint
Action:
① Loosen the tube clamp bolt at the cartridge body side.
② Extract the tube clamp and tube from the tube joint.
Tube clamp
Loosen this bolt.
Tube
Tube joint
Cartridge body side

Chapter 16 Dispenser
16-34
③ Loosen the tube clamp bolt at the syringe side.
④ Extract the tube clamp and tube from the tube joint.
Tube clamp
Loosen this bolt.
Tube Tube joint
Syringe side