M20_Ope_E.pdf - 第441页

959 %s Dump tray transfer error Check the conditions of Dump tray transfer. 912 %s Axis Position Error. Check Tray Feeder axis position. Servo off and move axis to normal position. 913 %s Tray Lock Error. Check Tray Lock…

100%1 / 518
911 Origin of %s is not taken. Check Tray Feeder.
850 Debris is detected. The placement is cancelled.
Debris is detected by Debris check. The placement is
851 Failed to output the image data.
cancelled.
Debris is detected by Debris check. Failed to output
the Image data file. The memory device may be full.
852 Image data file is not found. Image data file is not fount by Debris check.
853
854
Failed to read Image data file.
Internal process error: Failed to start Event reception.
Failed to read Image data file by Debris check.
Debris check: Internal process error: Failed to start
855
Internal process error: Event-reception-timeout error
occurred.
Event reception process RtOpenEvent().
Debris check: Internal process error: Failed to
response within set Event-reception-timout from
856
Internal process error: WinVision image-process-
WinVision image processing.
Debris check: Internal process error: WinVision image
857
program is aborted.
Internal process error: Failed to wait Event from
processing is aborted.
Debris check: Internal process error: Failed to receive
858
WinVision image processing.
Internal process error: Failed in HALCON function.
Response event from Vision image processing.
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
859 Internal process error: Failed in HALCON function.
processing. read_image()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
860 Internal process error: Failed in HALCON function.
processing. gauss_image()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
861 Internal process error: Failed in HALCON function.
processing. check_difference()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
862 Internal process error: Failed in HALCON function.
processing. closing_circle()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
863 Internal process error: Failed in HALCON function.
processing. opening_circle()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
864 Internal process error: Failed in HALCON function.
processing. connection()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
865 Internal process error: Failed in HALCON function.
processing. select_shape()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
866 Internal process error: Failed in HALCON function.
processing. count_obj()
Debris check: Internal process error: Failed to
execute HALCON function in WinVision image
867
Internal process error: Failed to get Shared image
address.
processing. sort_region()
Debris check: Internal process error: Failed to get
Shared image address in WinVision image processing.
868
Internal process error: Failed to get Shared image
data address.
(D_GetImageData)
Debris check: Internal process error: Failed to get
Shared image data in WinVision image processing.
869 Internal process error: Failed to unlink Image data file.
(D_GetImageData)
Debris check: Internal process error: Failed to unlink
900
Image data file in WinVision image processing. (unlink)
The board arrival sensor is ON at the timing to drive
901
PCB stopper.
The entrance sensor is ON at the timing to convey
902
out PCB.
Board jams between exit of pre-process and entrance
Check conveyor belts and conveyor motors.
903
sensor.
Board jams between exit sensor and entrance of
Check conveyor belts and conveyor motors.
post-process.
904 Board jams on %s. Check conveyor belts and conveyor motors.
905 Inspection NG PCB is on the conveyor. Remove the PCB from the conveyor.
906 Entrance Shutter error. Actuate Entrance Shutter in manual menu.
907
908
Exit Shutter error.
The head%d1 locates too low to exchange the pallet
Actuate Exit Shutter in manual menu.
Check head height.
909
of the %s.
Tray data of %s - Component height exceeds the
Check Component Height.
910
allowable limit.
Choke pressure error at nozzle exchange on Head%c1 Check for nozzle choke or component remaining on
with Nozzle No.%d2. %d3 > %d4. nozzle.
959 %s Dump tray transfer error Check the conditions of Dump tray transfer.
912 %s Axis Position Error.
Check Tray Feeder axis position. Servo off and move
axis to normal position.
913 %s Tray Lock Error. Check Tray Lock.
914 %s Supply Tray transfer hook ON. Check Supply Tray transfer hook.
915 %s Undefined Error. Check Tray Feeder.
916 %s Pallet Set Error. Check CTF.
917 %s Pallet Stopper Position Error. Check Pallet Condition.
918 %s Axis Command Error. Check CTF.
919
920
%s Docking Error.
Error status is detected on Coplanarity Checker.
AC100V is not supplied from mounter or Serial cable
Check CTF Docking Condition.
Check the connection between power switch at
sensor processor and serial cable(COM1). Contact us
921
is not connected with mounter. if it would not work properly still.
%s. %m %c4%c5 step No.%d2 for repeat offset step
922
No.%d3
Operation Enabling SW has not been pressed.
Operation by mouse or keyboard should be done with
the Operation Enabling SW being pressed.
923
924
Operation is not allowed while cover is open.
Immediate stop at pickup NG %m %s-%d3 Head%c1
Close the cover.
Check for pop-up attitude of the error component.
Nozzle No.%d2 Step:%d5 Offset:%d6
925 RTS-1 condition error. Check RTS-1.
926 Conveyer auto width error. ( Software limit over) Check width.
927
928
%s Parameter Search Error. Check CTF Parameter. ( System Parameter )
%m overload software limit. Head%s %c6 ( current %d1
929
limit %d2 %d3[%] count %d4 alarm %d5 )
Dump Status %c6%s (axis %d2, target %d4, current %d5,
930
direction, %d1, speed, %d7, status, %d3, command, %d8)
Detect Interlock %c6%s (axis %d2, target %d4, current
931
%d5, direction, %d1) (collision axis %d7, target %d8)
Distance between fiducial marks exceeds the limit.
Check Mark, Board, Lighting, and Image Library data.
932
Step:%d5 Offset:%d6
Conveyor Width cannot be changed because Main
Turn Off the Main Clamp.
Clamp is ON.
933 Request to change program for production %m
934
935
PCB code cannot be recognized.
The corresponding program to the detected %m PCB
Check the PCB code state to be recognized.
Create the program corresponding to the PCB code.
code does not exist.
936
937
Tape End Process. (END Signal Received)
%m Production Program Selected
A program has been selected by operator in the
938 Fluid Shortage Alarm Head%c1 Level%d2 Times%d3
Auto-switching of Production Program mode
Fluid is about to run out. Prepare a new syringe to
939 %s-%d1 %m is skipped.
replace.
Set the specified feeder to improve production
940 %s-%d1 %m is not set.
efficiency.
Check the feeder setting conditions. Improper setting
941
The vacuum sensor of the vacuum stage does not
may cause the feeder to collide with the head.
Check the vacuum stage.
942
turn ON.
Production Info. was not transferred. (Internal:%d1
Check LAN connections between machines.
Input:%d2 Conveyor:%s)
943
944
Inspection %s
The inspection of Production program%m, the number
945
of the PCBs %d has been skipped.
Servo error %c6%s (axis %d2, %e, sub code %d3, target
%d4, current %d5)
946 %c1 switch cannot be activated in %s.
947 %s Palette set error Check Tray Feeder.
948 %s No Feed trays Replenish trays in Feed tray rack.
949 %s Set up components error Check the setup switch status.
950 %s No pallet in stocker. (Pallet-%d2) Check MXR setting
951 SwapTray cover is open. Check SwapTray cover.
952 %s Drive error Check Tray Feeder.
953 %s Rack cover is open. Check Rack cover.
954
955
%s Tray rest is not set on Feed tray rack properly.
%s pallet partly moves out of the stocker. (Pallet
Check if Tray rest is set on Feed tray rack properly.
Check the transfer conditions.
transfer area sensor is turned ON. [ON:0/OFF:1])
956 %s Dump-tray push-lever error Check the conditions of Dump tray push lever.
957 %s Hook move position error System parameter may be incorrect.
958 %s Elevator drive position error System parameter may be incorrect.
1014 Image data results of Debris check could not be Check the destination to save image data is proper.
960
961
%s Elevator height error for tray transfer.
%s Elevator position sensor does not respond.
Tray may have not reached transfer height properly.
Check Elevator height detect sensor and Elevator
962 %s No trays on Tray feed table
motion.
Tray may not have come out from Feed tray rack
properly.
963 %s No trays on Tray dump table. Tray may not have transferred properly.
964 %s Tray is on Shuttle unit. Tray may not have transferred properly.
965 %s Feed tray transfer error Check Feed tray at the transfer point.
966 %s Full trays in Dump tray rack. Take out empty trays from Dump tray rack. (Max.30)
967 %s Full trays in Feed tray rack. Take out trays from Feed tray rack. (Max.30)
968 %s Tray is on Tray feed table. Feed tray may not have transferred completely.
969 %s Tray is on Tray dump table. Dump tray may not have transferred properly.
970
971
%s Position error
%s Hook position error for Elevator drive
System parameter may be incorrect.
Check Hook origin detect sensor or Hook transfer
972 %s Elevator height error for Shuttle transfer.
motion.
Check Elevator height detect-sensor or Elevator
drive motion.
973
974
%s Tray is on Shuttle unit.
%s Shuttle unit is not ready at Pickup point.
Tray may not have transferred properly.
While preparation of tray feeding, error may have
occurred.
975 %s Time out for Tray feed table Up Check Tray feed table.
976 %s Time out for Tray feed table Down Check Tray feed table.
977 %s Time out for Tray dump table Up Check Tray dump table.
978 %s Time out for Tray dump table Down Check Tray dump table.
979 %s Time out for Tray stopper of Feed rack Unlock. Check Tray stopper.
980 %s Time out for Tray stopper of Feed rack Lock. Check Tray stopper.
981 %s Time out for Rack cover Lock. Check Rack cover lock.
982 %s Time out for Rack cover Unlock. Check Rack cover lock.
983 %s Time out for Feed tray push-lever On Check Feed tray push lever.
984 %s Time out for Feed tray push-lever Off. Check Feed tray push lever.
985 %s Time out for Dump tray push-lever On. Check Dump tray push lever.
986 %s Time out for Dump tray push-lever Off. Check Dump tray push lever.
987 %s Shuttle tray unlock Time out Check Shuttle tray lock.
988 %s Shuttle tray lock Time out Check Shuttle tray lock.
989 %s Hook origin Time out Check Hook.
990 %s Elevator origin Time out Check Elevator.
991 %s Hook transfer Time out Check Hook.
992 %s Elevator drive Time out Check Elevator.
993 %s Feed tray unload error Error happened while tray transfers to Tray feed
994 %s Dump tray stack error Error happened while tray transfers to Tray dump
995 %s Tray exchange interlock error. Interlock error is detected during tray exchange.
996 Undefined Vis-error Code
997 Control Message Code Error %d8
998 MT-LOG component name %m
999 Internal Error 999 Contact us.
1000 Emergency stop. %s Remove the cause of the error.
1001 Instantaneous power failure is detected. Check capacity of power source.
1002 Power failure
1003 Safety area sensor responded. Remove the obstruct in the sensing area.
Check the cover lock mechanism and the open cover
1004 Open %s was detected in the AUTO mode.
sensors.
1005 Air pressure is low.
%s Abnormal temperature of regenerative resistor is
Check the air connector on the machine rear side.
Check the temperature of the regenerative resistor
1006
detected. and cables for breaks.
Check the AUTO/MANUAL switch or others to
1007 Servo OFF signal was detected.
CFB or CTF is not connected in %s. Connect CTF or
eliminate the cause for Servo OFF.
1008
CFB by DOCKING SWITCH.
Elevator axis belt of the FTF exceeds the belt slack
Connect CTF or CFB by DOCKING SWITCH.
1009
tolerance.
Contact us.
Motor/mechanical error. Check the axis coordinates
1010 Detected the %c6%s axis end limit (+).
and contact us.
Motor/mechanical error. Check the axis coordinates
1011 Detected the %c6%s axis end limit (-).
and contact us.
1012 Request MMI Condition Check!!
An error is detected by IO operation. Check the error
1013 IO error is detected. %e