Chapter 11 Parameter Setting 11-2 11-1 User Parameter 11-1-1 Reject Location Menu: System>UserParameter>RejectLocation Set coordinates to reject defective components. Up to 8 sets of coordinates can be registered. …

100%1 / 518
Chapter 11 Parameter Setting
11-1
Chapter 11
Parameter Setting
User Parameter
System Parameter
Chapter 11 Parameter Setting
11-2
11-1 User Parameter
11-1-1 Reject Location
Menu: System>UserParameter>RejectLocation
Set coordinates to reject defective components. Up to 8 sets of coordinates can be registered.
[Reject Location] setting in the packaging library and tray library is associated to the data
number (No. 3–10) in this tab.
The data lines, Reject Tray (F)/(R), are used when [Reject/Reuse] setting in pickup data is set
to “Standard” in case of ST-F or ST-R Feed Style data.
Action:
Click <Teach> button to open the Teach dialog box.
Bring the main teach camera to the desired position, and enter the coordinates.
Return to the User Parameter dialog box. Click <Save> button.
Click <Close> button to close the dialog box.
Chapter 11 Parameter Setting
11-3
11-1-2 Reject Conveyor Offset
Menu: System>UserParameter>RejectConveyorOffset
Set coordinate offsets for the component reject location on the reject conveyor. When using the
specified reject location (pickup coordinates of the station where the reject conveyor is
connected), the offset setting here is not necessary.
Up to 10 coordinate offsets can be registered. [Reject Location] setting in the pickup data is
associated to the data number (No. 1–10) in this tab when [Reject/Reuse] is set to “Reject
Location”.
Note: For information on how to use the reject conveyor, see the instruction manual for the reject
conveyor.