M20_Ope_E.pdf - 第454页

%d1 return MX-20 to origin. 1572 MX-20 Pallet detect sensor in Stocker is OFF. Pallet-%d1 Insert the specified Pallet into MX-20 stocker. 1534 %s Pallet detect sensor on hook ON. (Pallet-%d2) Check conditions of MXR 1535…

100%1 / 518
1531 %s Hook unlock sensor ON. (Pallet-%d2) Check conditions of MXR
1532 %s Hook unlock sensor OFF. (Pallet-%d2) Check conditions of MXR
1533 %s Stocker area sensor detected a pallet. Check conditions of MXR
1480
Measure DP %s( F:%d1 X:%d2 Y:%d3 AR:%d4 LS:%d5
1481
SS:%d6 SD:%d7 T:%d8 %m )
The component %m" in step No.%d1 for repeat offset
Remain Check:%d4)"
1482
step No.%d2 will be skipped. (Head%c3
The component %m" will be skipped from the step
No.%d1 for repeat offset step No.%d2. (Head%c3)"
The component exhaustion process for %m" will be
1483 postponed from the step No.%d1 for repeat offset
step No.%d2."
1484 Paused for component exhaustion. Replenish the feeder with components to restart.
1485
Production was started with the Postpone
Component Exhaustion Process" function disabled."
To enable the Postpone Component Exhaustion
Process" function
1486
1487
Out of components (%m).
The component %m" in step No.%d1 for repeat offset
Refill the components.
1488
step No.%d2 will be postponed."
Buffer stopper error
Actuate buffer stopper in manual menu
1489
Changed to safety stop" state because %s was
(Actuator/LoadBoard).
To resume production run, close the cover and press
opened." the Servo switch.
1490
Switched to %s mode and changed to safety stop"
state."
To resume production run, close the cover and press
the Servo switch.
1491
1492
Switched to %s mode.
Switched to %s mode and changed to safety stop" To resume production run, close the cover and press
state." the Servo switch.
1493
Coordinates have been lost due to trouble in return-
to-coordinate process.
Take origin again.
1494 %c1 switch cannot be activated because %s is open. Close the cover.
1495
Job run cannot be performed because the machine is
Press the Servo switch.
in the safety stop" state."
1497
1500
%m
%s Pallet exists on hook. (Pallet-%d2)
Message
Check MXR setting
1501
1502
%s No pallet on hook. (Pallet-%d2)
%s Pallet exists on hook whereas pallet not
Check MXR setting
Check MXR setting
programmed. (Pallet-%d2)
1503
%s No pallet on hook whereas pallet programmed.
Check MXR setting
1504
(Pallet-%d2)
%s Pallet exists in stocker. Check MXR setting
1505
1506
%s No pallet in stocker. (Pallet-%d2)
%s Pallet exists in stocker whereas pallet not
Check MXR setting
Check MXR setting
programmed. (Pallet-%d2)
1507
%s No pallet in stocker whereas pallet programmed.
Check MXR setting
(Pallet-%d2)
1508 %s Pallet No. Failure in Stocker. (Pallet-%d2) Check MXR setting
1509 %s Timeout for door lock. (Pallet-%d2) Check conditions of MXR
1510 %s Timeout for door unlock. (Pallet-%d2) Check conditions of MXR
1511 %s Timeout for hook lock. (Pallet-%d2) Check conditions of MXR
1512 %s Timeout for hook unlock. (Pallet-%d2) Check conditions of MXR
1513 %s Timeout for pallet bar open. (Pallet-%d2) Check conditions of MXR
1514 %s Timeout for pallet bar close. (Pallet-%d2) Check conditions of MXR
1515 %s Timeout for pallet side clamp ON. (Pallet-%d2) Check conditions of MXR
1516 %s Timeout for pallet side clamp OFF. (Pallet-%d2) Check conditions of MXR
1517 %s Timeout for pallet rear clamp ON. (Pallet-%d2) Check conditions of MXR
1518
1519
%s Timeout for pallet rear clamp OFF. (Pallet-%d2)
%s Timeout in Elevator Movement. (Pallet-%d2)
Check conditions of MXR
Check conditions of MXR
1520 %s Timeout in Hook Movement. (Pallet-%d2) Check conditions of MXR
1521
%s Timeout for Elevator Returning to Origin. (Pallet-
Check conditions of MXR
%d2)
1522 %s Timeout for Hook Returning to Origin. (Pallet-%d2) Check conditions of MXR
1523 %s Pallet advance end sensor ON. (Pallet-%d2) Check conditions of MXR
1524 %s Pallet advance end sensor OFF. (Pallet-%d2) Check conditions of MXR
1525 %s Pallet bar open sensor ON (Pallet-%d2) Check conditions of MXR
1526 %s Pallet bar open sensor OFF (Pallet-%d2) Check conditions of MXR
1527 %s Pallet bar close sensor ON (Pallet-%d2) Check conditions of MXR
1528 %s Pallet bar close sensor OFF (Pallet-%d2) Check conditions of MXR
1529 %s Hook lock sensor ON. (Pallet-%d2) Check conditions of MXR
1530 %s Hook lock sensor OFF. (Pallet-%d2) Check conditions of MXR
%d1 return MX-20 to origin.
1572
MX-20 Pallet detect sensor in Stocker is OFF.
Pallet-%d1
Insert the specified Pallet into MX-20 stocker.
1534 %s Pallet detect sensor on hook ON. (Pallet-%d2) Check conditions of MXR
1535 %s Pallet detect sensor on hook OFF. (Pallet-%d2) Check conditions of MXR
1536 %s Pallet side clamp sensor ON. (Pallet-%d2) Check conditions of MXR
1537 %s Pallet side clamp sensor OFF. (Pallet-%d2) Check conditions of MXR
1538 %s Pallet rear clamp sensor ON. (Pallet-%d2) Check conditions of MXR
1539
1540
%s Pallet rear clamp sensor OFF. (Pallet-%d2)
%s Hook-axis is out of origin position. (Pallet-%d2)
Check conditions of MXR
Check conditions of MXR
1541
1542
%s Hook-axis is out of supply position. (Pallet-%d2)
%s Failed in Assigning Elevator Moving Position
Check conditions of MXR
Check conditions of MXR
(Pallet-%d2)
1543
%s Failed in Assigning Hook Moving Position (Pallet-
Check conditions of MXR
1544
1545
%d2)
%s Door Open (Pallet-%d2)
%s Elevator Slow-down Stop (Pallet-%d2)
Check conditions of MXR
Check conditions of MXR
1546
%s Pallet Interlock. Remove the pallet in the middle of
being supplied and check in the Manual menu. Then Check conditions of MXR
1547
perform axis zeroing.
The relay hook of MX20 is not in Stocker Position for
Secure the safety of MX20 unit and take origin.
Relay" position."
1548
No PCB has been selected in the PCB select bad
mark" process."
Check the board for bad marks.
1549 Nozzle No.[%d2] is not found in nozzle library. Check nozzle library.
1550 Cannot perform dispense check.
Check the image library and the image code in the
1551 Cannot capture an image in dispense check.
dispense library.
Process is not properly performed. Contact us.
1552
1553
Syringe change signal for Head%c1 has been
The nozzle set in the dedicated ANC is different from
Acception parameter for syringe has been initialized.
Check nozzle setting.
1554
specified one. ANC(%d1)
Nozzle is set on the Head%c1.
Check ANC shutter and missetting of nozzle. Contact
us for ANC scanning error.
1555
1556
Communication fails.
System status is changed.
Cancel command cannot be sent to the vision
system. Contact us.
System diagnoses itself.
1557
Head%s Dispense Correction OK count:%p2 Average
ratio:%d3% Tolerance:%d4%-%d5% Correction
Value:%v8Mpa Pressure:%v6Mpa Retry Count:%d7 %m
Executing Dispense Correction
1558
Head%s Dispense Check OK OK count:%p2 Average
ratio:%d3% Tolerance:%d4%-%d5% Pressure:%v6Mpa
Correction coefficient:%v1 Retry Count:%d7 %m
Dispense Check Passed
1559
Short of nozzles for the current program. Nozzle:%d1
Number of Nozzles:%d2 Number of set nozzles:%d3
Number of shortage nozzles:%d4 %s
Set the required nozzles.
1560
Shortage of the optimum number of nozzles.
Nozzle:%d1 Optimum number:%d2 Set number:%d3
Set the proper number of nozzles for efficient
production.
1561
Short number:%d4 %s
Automatic nozzle arrangement will be skipped
Check the setting in User Parameter > Functions.
1562
according to the user parameter setting.
Auto nozzle arrangement cannot be performed
Release the Fixed Nozzle setting for head 1 and 2.
because head 1 and/or 2 are set for Fixed Nozzle"."
1563
Component %m" is not set on %s-%d1. Feeder ID
%d2-%d3"
Confirm the component on the feeder.
1564
1565
The program cannot be run since feeder is
Exceeded the maximum correction value. %s(X:%d1
Y:%d2 T:%d3) Head%c4 %m
Confirm the feeder location.
Click the <LOG> button to obtain Log data, and
contact us.
1566
Remove the pallet-%d1 from the tray feeder. It must
be done while the Servo motor is off.
Turn off the Servo motor from the Maintenance
Menu. Remove the pallet, which was failed to be
1567
The nozzles required for the production are not set at
delivered, out of the tray feeder and return all the
Set the nozzle at proper position where the head can
1568
proper position of ANC. Head%c1 Nozzle:%d2
Z-axis did not reach the pickup height when pickup.
use.
Check the Head Z axis condition.
1569
Head%c1 Nozzle:%d2
Z-axis did not reach the placement height when
Check the Head Z axis condition.
1570
placement. Head%c1 Nozzle:%d2
Z-axis did not reach the Reject/Return height when
Check the Head Z axis condition.
1571
Reject/Return Component. Head%c1 Nozzle:%d2
MX-20 Pallet detect sensor in Stocker is ON. Pallet- Remove the specified Pallet from MX-20 stocker and
1619 Teaching ends.
1620 Manual ends.
1621 Origin detection ends.
1573 PCB Vacuum Error. Check PCB Vacuum for error.
1574
MX-20 Relay Hook Retract End Sensor Off (Pallet-
Check conditions of MX-20.
1575
%d1)
Start %s (%d1,%d2,%d3,%d4,%d5,%d6,%d7,%d8)
1576 End %s (Total:%d1 NG:%d2 Time:%d3.%d4sec)
1577
Error is detected on %s-%d1(Count:%d1 NG
Count:%d2Code:%d3 ID:%d4-%d5)
1578
1579
Skip %s %d1 times.(NG:%d2 Time:%d3.%d4sec)
Communication error happened between Mounter
Check the ID Database Server and LAN condition.
1580
and Feeder ID Database.(%d1<%d2msec)
Feeder position error. %s-%d1 -> %c4-%d5 %m" Feeder set position is wrong. Relocate it to the
1581
ID:%d2-%d3"
Feeder position error. %s-%d1 -> %c4-%d5 %m"
specified.
Feeder set position is wrong. Relocate it to the
ID:%d2-%d3" specified.
1582 Set position: %s-%d <- %m""
Remove the feeder from the specified station and set
the component.
1583
1584
Set position: %s-%d <- %m""
Component %m" has already been set."
Set the component to the specified station.
This component has already been set.
1585
1586
Component %m" is not used for this production."
Lead/Ball Height deviation is out of tolerance.
This component is not used for this production.
Check Lead/Ball floating condition and Lead/Ball
1587
Head%c1 %m
Lead/Ball Position XY deviation is out of tolerance.
Height Tolerance value.
Check Lead/Ball bending condition and Lead/Ball
1588
Head%c1 %m
No Lead/Ball-like object is found in measuring image.
pos. XY Tolerance value.
Check component data/thickness/condition.
1589
Head%c1 %m
Component image is out of measuring image range.
Check component data/thickness/condition.
1590
Head%c1 %m
Measured position of Lead/Ball markedly differs from
the setting of component data. Head%c1 %m
Check component data/thickness/condition.
1591
Lead/Ball is missing at predetermined location.
Head%c1 %m
Check Lead/Ball condition and settings of Component
Feature, Darkness level, Lead/Ball Pitch, and
1592
Tilt amount of Reference Surface is out of tolerance.
Lead/Ball Width in Coplanarity Check data.
Check component tilt condition and value of Tilt
1593
Head%c1 %m
Coplanarity Check Error occurred. Head%c1 %m
Tolerance of Ref. Surface in Coplanarity Check data.
Check component data/thickness/condition. Refer to
Error Code List for details.
1594 Fails to perform Coplanarity Check.
Check Coplanarity Check Unit and Communication
1595 Fails to capture the image at Coplanarity Check.
cables for any abnormal conditions.
Process is not properly performed. Contact us.
1596
1597
Fails to acquire the result at Coplanarity Check.
The head cannot reach a nozzle.
Process is not properly performed. Contact us.
Change a pickup head or the nozzle position. Or
enable the Automatic Nozzle Arrangement.
1598
Exceeded the maximum correction value. %s(X:%d1 Check that the maximum correction value is set
Y:%d2 T:%d3) Head%c4 %m properly.
1599 Improper component feeding %s #%d1 Head%c2 Stop operation and check feeding conditions.
1600 Processing ends. (servo motor off)
1601 Edition in pause.
1602 Teaching is possible. Perform operation safely. Each axis operates in safety speed.
1603 Manual is possible. Perform operation safely. Caution: Z axis does not move in safe height.
1604 Ready (Alarm off and recovery possible)
1605 Pause (Cancel or start possible)
1606 Run (Press cycle stop for stop and cancel for end)
1607
1608
Drive OFF
Maintenance possible.
Drive ON possible
Servo off for operation
1609 Alarm of servo/DC motor %s Check servo unit.
1610 Servo of caused by emergency stop
Emergency stop is pressed. System detects trouble
automatically.
1611 Wait until origins are taken. Each axis is taking its origin.
1612 Wait until movement ends.
Axis moves to specified coordinates. Press
emergency stop switch to stop movement.
1613 Load board
1614 starting signal is accepted. Data for run is collected.
1615 Run-starting-signal is accepted. Data for run is collected.
1616 Quit the system. Power is automatically turned off.
1617 Performance record is collected. Performance record is written on management data
1618 is saved. Data is saved on file. Use to prevent mis-saving.