M20_Ope_E.pdf - 第468页

3075 Pallet information of %s and pallet positions in stocker are not match. The machine recovered automatically. Check pallet positions in stocker. 3076 Head stops while waiting for completion of CTF/FTF tray setup 3041…

100%1 / 518
Result %d1 Default %d2 sure Z-axis moves smooth.
3039
The detected number of push-up pins and the
registered number of push-up pins do not match.
(Registered %d1: On Holder %d2: On Push-up Plate
Compare the number of push-up pins on the holder
and the registered number of pins.
3040 An error occurred while the CTF was initializing. Check the CTF.
3002
%s Origin recovery process is interrupted because
emergency stop is detected.
Check the machine condition and re-execute origin
recovery.
3003
3004
3005
%s Software limit over Specified coordinates are out of range.
Could not detect a mark on the conveyor rail. Check the mark condition.
Docking connector is not connected. %s %c1 Connect the CTF or the shorting plug to the mounter.
3006 Docking connector is disconnected. %s %c1
The CTF or the shorting plug is disconnected. Turn
off the mounter and check for any problems.
Difference of %s axis coordinates between the
3007 counter encoder and the motor encoder at the
machine startup exceeds the tolerance. Shift:%d1
Shift value of %s axis between the counter encoder
3008 and the motor encoder varied after machine startup.
Variation:%d1 Tolerance: %d2
3009
Shift value of the base mark exceeds the tolerance.
Shift:(%d1,%d2) Tolerance:(%d3,%d4) Check the base mark.
3010
Coodinates:(%d5,%d6)
Result of PCB check height exceeds the limit.
Check the warp check point.
Result:%v2mm, Default:%v3mm, Difference:%v1mm
3011
Head height result is not proper. Displacement: %d1,
Limit: %d2
Check the head and the base mark.
3012
3013
Head error occurred on the same head the height was
measured. Hence the measured height became invalid.
Cannot connect CTF during production.
When production is reset, head height will be
measured at next production.
Reset the production or connect CFB.
3014
Cannot perform conveyor height correction without a
Set a Nozzle 005 in the ANC.
Nozzle 005.
The mounter stopped by pickup error of the stick
Nozzle may hit a remaining component. Check the
3015 feeder %m %s-%d3 Head%c1 Nozzle%d2 Step:%d5
Offset:%d6
pickup point.
3016
3017
IO board connection error. Port%d1
Resume production from program row %d1 of repeat
Contact us.
3018
offset row %d2 by skipping row %m.
Height measurement error is found at result check.
Check that there is no debris at a measurement point.
3019 Nozzle did not reach the measurement height.
Also make sure Z-axis moves smooth.
Measurement height is too low or measurement point
3020
Cannot attach or remove the CFB/CTF when cover
is shifted.
Open the cover.
is closed.
3021
Nozzle damage alarm Head%c1 Nozzle%d2 Limit %d3 The nozzle vacuum pressure is not proper. Check the
3022
> %d4
Conveyor parallelism exceeds the tolerance. (Result):
nozzle.
Check the conveyor.
3023
%d1[Micrometer] > (Tolerance): +/- %d2[Micrometer]
CTF pallet transfer error Check the CTF.
3024 Fixed camera correction tool is not set. Set the fixed camera correction tool.
3025 Fixed camera correction tool cannot be recognized.
Check that no dirt or damage of the fixed camera
correction tool.
3026 Push-up pin is detected on the head %s.
Remove the push-up pin and the manipulator from
the head.
3027 Pin manipulator is not found. Replace the pin manipulator on the holder.
3028 The shutter of the pin manipulator is not open. Check the pin manipulator.
3029
3030
Pin manipulator fitting error (%e)
Pin manipulator remove error (%e)
Check the manipulator and the holder.
Check the pin manipulator on the head and remove it
3031 Push-up pin hold error (%e)
manually.
Check push-up pins on the holder.
3032 Push-up pin locate error Check push-up pins on the holder.
3033 Push-up pin remain error, Holder station %d1
Remove the push-up pin and the manipulator from
the head and check that no damage on them.
3034 Insufficient push-up pins (%d1>%d2)
Replace the registered number of push-up pins on the
holder.
3035
3036
No more places to replace push-up pins on the holder
Allocated push-up pins are not found on the push-up
Remove push-up pins from the holder.
3037
plate. (%d1,%d2)
Not all the allocated push-up pins can be replaced on
the holder. (%d1>%d2)
Check that no push-up pins laying on the push-up
plate.
3038
The height result exceeds the limit and is ignored. Check that no obstacles are at a check point. Make
3075
Pallet information of %s and pallet positions in stocker
are not match. The machine recovered automatically.
Check pallet positions in stocker.
3076
Head stops while waiting for completion of CTF/FTF
tray setup
3041
3042
The CTF stopped. An error occurred on the other
than the CTF while the CTF was operating.
Check the CTF.
Feeder type set at %s-%d1 and %m in pickup data do Check that feeder type input in pickup data and the
3043
not match.
Failed to perform CFB correction.
feeder type set at the specified position are the
Check that correction marks are clean.
3044
%c4 does not reach the target coordinates.
(Head%c6%s Target %d1 Pushdown Stroke %d5
3045
Feedback %d2 Tolerance %d3 %m)
Fixed nozzle is specified to Head%d1 that handles the
Cancel the fixed nozzle setting.
3046
manipulator.
Head cannot travel in XY directions because of Z axis
Check Z axis status.
error.
3047
%d2mm component pitch is not available for the
feeder %m set at %s-%d1.
Select available component pitch.
3048 Electropneumatic regulator error
Check the electropneumatic regulator and the
communication path.
3049
3050
An error occurred while dispensing.
DotStation is not registered in Pickup Data.
Contact us.
Create DotStation row in Pickup Data and specify
Station No.
3051
3052
DotStation is not mounted at %s-%d1. Check DotStation.
Dispense head cannot exchange nozzles. Dispense head tried to exchange nozzles.
Head%s Dispense Correction OK count:%p2 Average
3053 ratio:%d3% Tolerance:%d4%-%d5% Pressure:%v6Mpa
Correction coefficient:%v1 Retry Count:%d7 %m
Executing Dispense Correction
3054
Dispense head%s height check error, Difference:
%v1mm Tolerance:%v2mm Laser check:
3055
%v3mm,%v4mm Encoder check: %v5mm,%v6mm
Feeder pitch error. %s-%d1 %m (Skipped pickup data To restart, undo the un-skipped rows or press Reset
3056
of F3 cannot be reset during a job.)
Temperature reached target temperature. For your
safety, the machine will pause.
switch.
Clear the alarm. Then restart the job.
3057
Height offset of DP head%s is out of tolerance.
Offset:%v1mm, Tolerance:%v2 to %v3mm
Check that dispense nozzle is attached securely.
3058
Dispense recheck of Head%s OK count:%p2 Average
ratio:%d3% Allowable range:%d4%-%d5% Dispense check retry will be performed.
3059
Pressure:%v6Mpa Correction coefficient:%v1 Retry
PCB warp check point exists outside of PCB. %s
Check point %d1 Limit %d2
Check that no placement data exists outside of PCB
area.
3060
Motor alarm is detected on %c2%s when Ready switch
is turned On. (Alarm code %d1 %e)
3061
By PCB height check, measured height or calculated
correction height exceeds the tolerance. Step:%d1, Check that there is no obstacle or dirt on PCB.
3062
Offset:%d2
Failed to execute PCB warp check. Coordinates X: Check that there is no through-hole or notch at
3063
%v1mm, Y: %v2mm
Laser check results are unstable. Coordinates X:
check points.
Check that there is no obstacle or dirt on PCB.
3064
%v1mm, Y: %v2mm
Comp Pitch of Feeder %m at %s-%d1 is changed from
3065
%d2mm to %d3mm.
Auto PCB warp check is available up to 10000 rows
Select Manual.
including repeat task rows.
3066
Feeder setup is verified. Feeder setup count %d1,
Feeder count in Pickup data %d2
3067
Feeder setup count %d1, Feeder count in Pickup data
%d2
3068 Server access timeout is detected. %s-%d1 ID:%d2- Check the connection of the server.
3069
F3 feeder information %s-%d1 %m, Serial No.%d3,
Component pitch %d4mm, Internal error code %d7 %e
3070
All push-up pins are on the holder. (Registered: %d1,
3071
3072
On Holder: %d2)
%s was changed to the setup state.
%s was changed to the components supply state.
3073
3074
%s stocker cover is open.
%s servo is off.
3107 Failed to image the pickup point. Row:%d1 Offset:%d2
image data.
3108
Extra time was needed to start stable Laser check.
%d1msec
3109
IC component feeding device is out of components or
a malfunction occurred in the device.
Please check IC component feeding device.
3077
Head will start traveling after completion of CTF/FTF
tray setup
3078
The component cannot be put back to the tray for
reuse because %s is in Nonstop tray setup mode. To
Press Setup switch to allow CTF/FTF to supply
components.
3079
cancel the mode, press Setup switch.
Laser calibration is interrupted.
3080
3081
Laser calibration error occurred.
Laser tool horizontal error
Tool is not horizontally assembled. Check the
3082 Laser height scale error
assembled condition.
Re-adjust the laser head assembling. Then re-
3083 Laser height check range error
execute auto calibration.
Re-adjust the laser head assembling. Then re-
3084 Laser Z offset check error
execute auto calibration.
Re-adjust the laser head assembling. Then re-
3085
3086
Laser XY offset check error
Laser immeasurable check error
execute auto calibration.
Re-execute provisional adjustment of XY offset. Then
execute auto calibration.
Make sure no dirt or obstacles are at laser transmit
part. Then re-execute auto calibration.
3087
Cannot set the feeder at the pickup station because
the feeder pickup point height exceeds the height of
limit range. %s-%d1 %m %v2mm < %v3mm
To set the feeder at a feeder station, 'ST-F1 to 13 on
M10', or 'ST-FR24 to 36 or ST-FL1 to 13 on M20',
feeder pickup point height, sum of Pickup 'Z offset' +
Feeder 'Feed height' + Package 'Height'" must be
5mm or less. (Minus Z offset is not added.)"
To set the feeder at a pickup station, 'ST-F1 to 13 on
Cannot set the feeder because Device Max Height of
M10', or 'ST-FR24 to 36 or ST-FL1 to 13 on M20',
3088 the feeder exceeds the height of limit range. %s-%d1
sum of the device max height and the feeder height
3089
%m %v2mm < %v4mm
%s communication error
must be 5mm or less.
3090
3091
%s servo error
READY %s X,%d1,Y,%d2,Z,%d3,%d4,%d5,%d6,%d7,%d8
3092 READY %s R,%d3,%d4,%d5,%d6,%d7,%d8
Angle of Dispense nozzle exceeds tolerance. Head%d1
3093
Shift: %v2 Tolerance: %v3
Refix the Dispense nozzle.
Never set a feeder during production to prevent a
3094 A feeder is set at %s-%d1 during production.
head crash.
A feeder is removed from %s-%d1 during production. Never remove a feeder during production to prevent a
3095
(The feed button of F1 or F2 feeder was pressed.) head crash.
Comp Pitch of Feeder %m at %s-%d1 is changed from
3096
%d2mm to Default.
Comp Pitch of Feeder %m at %s-%d1 is changed from
3097
3098
Default to %d3mm.
Comp Pitch of Feeder %m at %s-%d1 is selected to
Default.
Comp Pitch of Feeder %m at %s-%d1 is selected to
3099
%d2mm.
Image process is resulted in NG because failed to
3100 acquire the acceleration and/or the speed of image
capture. %m Head%c1
3101 Failed to check Dispense nozzle length. Head%d1
The offset value in the dispense data exceeds
Check that Dispense nozzle is attached properly.
Correct the offset value in Dispense Data to be within
3102
DotStation area.
Component is placed out of PCB %m Head%c1
DotStation area.
Check PCB size, placement point, component data,
3103
Row:%d5 Offset:%d6
Placement error reaches limit count. %m Head%c1
selected nozzle, and image data.
Check PCB size, placement point, component data,
3104
Row:%d5 Offset:%d6 selected nozzle, and image data.
Shortage of disk space or cannot connect a network
3105 Cannot save a log file.
drive.
Cannot drive because version of the right and the left
3106
servo amplifiers differ. Y1-AMP:%X1 Y2-AMP:%X2
Use X and Y Servo amplifiers of version E4.001.
Check the Pickup point status and the Component