1384 ANC operation error Check ANC shutter and missetting of nozzle. Contact us for ANC scanning error. 1339 Communication error in image process 1340 1341 Component lack. Setup is possible %s #%d1 Pickup points of compo…

1338 %s CFB is not set.
CFB's set sensor is not responding. Set CFB in
position.
1293 MX-20 Elevator Slow-down Stop (Pallet-%d1) Check conditions of MX-20.
1294
Manual opening of ANC is detected. Unconformity in
nozzle info. may occur. Job run cannot be continued.
Perform nozzle scanning.
1295
Cannot continue operation. Machine origin
unidentified.
Select <Edit&Teach> button, and perform Origin
Initialize again.
%s Returning to Origin. Origin Sensor Z-phase
1296
1297
Distance Error(Z:%d1 - O:%d2 = %d3 > %d4)
%s operation error (Pallet-%d2)
Check the origin sensor and Z-phase input.
Check pallet information or MXR.
Paper shortage of DotStation or DotStation position Refill paper of DotStation. Or check pickup station
1298
error occurred. No. of DotStation.
1299 Dot station motor alarm. Check for cleaning paper jam or motor problem.
1300 Standard device %c4%c1%s initialization error (%e) Error at control board/driver. Contact us.
1301
1302
Program error. Failed to initialize the task.
Program error
System error. Contact us.
System error. Contact us.
1303
Drive signal is not turned On. (The cover may not be
closed properly.)
System error. Contact us.
Motor alarm at the initialization of %c4%c2%s. (alarm Turn off servomotors via Maintenance>ServoOff. Ten
1304
1305
code %d1)
Option device %c4%c1%s is not initialized properly. (%e)
minutes later, turn them on.
Error at control board/driver. Contact us.
Check the setting of IC card and communication
1306 Vision system initialization error
cable. Restart the system.
1307 Air pressure at initialization is abnormal. Check the air piping and restart the system.
1308 Command sequence error Contact us.
1309 Paused for postponed retry steps. Press <Recovery> switch and then <Start> switch.
1310 Improper component feeding %s #%d1 Head%c2 Stop operation and check feeding conditions.
1311 No available feeder %s #%d1 Head%c2 Stop operation and check for presence of feeder.
1312
1313
Feeder error Head%c1
Improper component feeding %s #%d1
Out of component or no component at pickup point.
Stop running and check the feeding conditions.
1314 Job run is paused.
Set up the mounter and resume job run by pressing
<Recovery> and <Start>.
1315
Component is detected on the nozzle in comp.
Remain Check.
Check the pickup/placement and take proper
measures in the Edit & Teach mode.
%m PCB code mismatch was detected. Auto program
1316
1317
change was performed.
%m PCB code mismatch was detected.
Auto program change was performed.
PCB code mismatch was detected.
Nozzles on heads and Nozzle Information do not If the machine does not recognize nozzle IDs properly,
1318
1319
match.
No program step to execute.
contact us.
Check the program setting (skip assignment, etc.).
1320
Reached the limit of vision-process retry count (%m
%s-%d3 Head%c1 Nozzle No.%d2 Step:%d5
Check the image library data and illumination setting.
1321
Reached the limit of pickup retry count (%m %s-%d3
Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Check the pickup coordinates and nozzle choice.
1322
Reached the limit of feeder retry count (%m %s-%d3
Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Check the component feeding conditions.
1323
Out of component (%m %s-%d3 Head%c1 Nozzle
No.%d2 Step:%d5 Offset:%d6)
After replenishing components, update the component
count setting.
1324
Reached the limit of choke-pressure retry count
(Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Check the air pressure, air filter, and nozzle data.
Check that the component feeder is mounted. Check
1325
Usable feeder is not mounted. Head%c1, Nozzle
No.%d2, Step:%d5, Offset:%d6
that the feeder is mounted on the head reachable
station.
Reached the limit of coplanarity retry count (%m %s- Check the component's image code and coplanarity
1326
1327
%d3 Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Timeout in coplanarity check
data.
Check the wiring of the LIM unit.
Check the power to the LIM unit. Check the wiring of
1328 Power to the LIM unit is off.
the LIM unit.
1329 LIM unit is in the local mode. Switch the LIM unit's mode to the host mode.
1330
1331
Out of component. %s #%d1
Out of component. %s #%d1 (P%d2#-%d3 pallet)
Replenish components.
Replenish components.
1332 Components are running out. %s #%d1 rest %d2 pcs.
Components are used down to
Program>PickupData>ShortageAlarm setting.
Components are running out. %s #%d1 (P%d2#-%d3 Components are used down to
1333
pallet) rest %d4 pcs. Program>PickupData>ShortageAlarm setting.
1334 Failed to lock CFB %s. Check CFB lock mechanism.
1335 Failed to unlock CFB %s. Check CFB lock mechanism.
1336
1337
Setup ready error
Setup complete error
Check CFB lock mechanism.
Check CFB lock mechanism.

1384 ANC operation error
Check ANC shutter and missetting of nozzle. Contact
us for ANC scanning error.
1339 Communication error in image process
1340
1341
Component lack. Setup is possible %s #%d1
Pickup points of component lack are displayed.
Replenish components.
Vision process sequence error. Execute system
1342
recovery.
Check Vision processing unit or Cables for error.
1343 Failed to clamp MX-ST2. Failed to clamp MX-ST2.
1344 Failed to unclamp MX-ST2. Failed to unclamp MX-ST2.
1345 %s pallet setting error (Pallet-%d2) Check pallet information or MXR.
1346
1347
%s origin acquisition error (Pallet-%d2)
Cannot supply components from %s.
Check conditions of MXR.
Check the feeder.
The feeder is specified as unavailable feeder. %s Clear the Feeder Skip state for concerned pickup
1348
1349
#%d1
AMF measurement ends.
point(s).
1350 Setup error
This error is caused by effect of other errors. Check
the other error messages near around.
1351
Retry step postpone table is full. Execute normal
retry process.
Retry step postpone table is full. Execute normal
retry process.
MAP measurement ends. Press Start SW to convey
1352 MAP measurement ends.
out the board.
1353
1354
Axis movements are unstable.
Axis movements are unstable.
There are no usable pickup points because the
Contact us.
Contact us.
1355 machine is in the changeover state. (%m %s-%d3
Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
End the changeover state.
1356 Reject conveyor on %s %d1 is almost out of space.
There are no usable pickup points because Feeder
Components on Reject conveyor are almost full.
(Warning!)
1357 Skip is/are specified. (%m %s-%d3 Head%c1 Nozzle
Clear the Feeder Skip state for concerned pickup
1358
No.%d2 Step:%d5 Offset:%d6)
Controller error
point(s).
System is not operating properly. Contact us.
Check the code entry equipment for settings and
1359 PCB code entry error connections. To continue the job run, check the PCB
code and select the program.
1360 %s Motor alarm
Execute Maintenance>ServoOff. Ten minutes later,
turn on <Servo> switch.
Coordinates exceeded the setting of
1361 %s position exceeded the limit. SystemParameter>WorkRange or
SystemParameter>Axis>TravelDist.
1362 %s detected EL(+). Overrun. Take origin again.
1363 %s detected EL(-). Overrun. Take origin again.
1364 Origin of %s is not taken. Check Origin menu.
1365
1366
%s error
Error occurs at %s.
Remove error.
Remove error.
1367 %m PCB code is not defined in the Plan.
Define the PCB code in the Plan and select the
program.
Fiducial correction was not performed. Change the
1368 Fiducial error (4point)
mark location.
1369
1370
Timeout in %s operation.
ANC slide channel operates improperly.
Check cylinders, motors, and sensors.
Check cylinders and sensors.
This nozzle station is not for removing nozzles from
1371 The nozzle cannot be removed from the head.
heads.
1372 Error occurs in image processing. Check image process system and communication
1373 Device cannot be initialized. Contact us.
1374
1375
Error in opening PS-BC shutter. %s (%d1)
Error in closing PS-BC shutter. %s (%d1)
Check the shutter mechanism of the bulk feeder.
Check the shutter mechanism of the bulk feeder.
1376 Main clamp is abnormal.
Check support pin for crash. Check adjust plate for
foreign matters.
Check PCB stopper for normal operation st Manual
1377 PCB stopper is abnormal.
menu.
1378 Rear clamp is abnormal. Check rear clamp for normal operation.
1379
1380
Side clamp is abnormal.
ANC shutter is abnormal.
Check side clamp.
Check ANC shutter.
Computing error for correction. Save Log file and
1381 Fiducial error (calculation)
contact us.
1382
1383
Conveyor error
Disconnect the cable and air tube for the CFB.
Check conveyor transfer belts and motors.

%d8 Step:%d5 Offset:%d6
pressure.
1439 Clamp MX-ST2. Clamp MX-ST2.
Check ANC shutter and missetting of nozzle. Contact
1385 ANC scanning error
us for ANC scanning error.
1386 MX-40 pallet setting error Check pallet information or MX-40.
1387 MX-40 origin acquisition error Check MX-40.
1388 MX-40 shuttle contacts conveyor rail. Check conveyor rail position.
1389 Feeder cannot operate. Check feeder for misfeeding.
1390 Signal output operation error System is abnormal. Contact us.
1391
1392
PS-32A tape-peeling error %s (%d1)
PS-32A re-positioning error %s (%d1)
Check Feeder Setting or check the feeder.
Check Feeder Setting or check the feeder.
PS-32A sequence clear command control error %s
1393
(%d1)
Check Feeder Setting or check the feeder.
1394 MX-20 pallet setting error (Pallet-%d1) Check pallet information or MX-20.
1395 MX-20 origin acquisition error (Pallet-%d1) Check MX-20.
1396 MX-F20 shuttle contacts conveyor rail. Check conveyor rail position.
1397 Failed to retract MX-40 pallet Check MX-40 setting and conditions of MX-40B
1398 Failed to retract MX-20 pallet (Pallet-%d1) Check MX-20 setting and conditions of MX-20F
1399 Failed to retract %s pallet (Pallet-%d2) Check pallet information or MXR.
1400 %m
1401 %s is open.
1402 %s is pressed.
1403 Origin detection starts.
1404 Sensor of the safety guard responded.
1405 Origin has been detected.
1406 Waiting for Board arrival at %s. Waiting for Board arrival.
1407 Board starts to enter at %s. Just started Board transfer in.
1408 Board has arrived at %s. Completed Board transfer in.
1409 IN sensor detects board.
1410 Buffer sensor detects board.
1411 Arrival sensor detects board.
1412 OUT sensor detects board.
1413 Board clamp starts.
1414 Board clamp ends.
1415 Board unclamp starts.
1416 Board unclamp ends.
1417 Board is ready to be conveyed out at %s. Board is ready to be conveyed out.
1418
1419
Board starts to be conveyed out at %s.
Board has been away from %s.
Just started Board transfer out.
Completed Board transfer out.
1420
Canceled the job with the multiple-pickup cycle
halfway done.
When production is cancelled without completing
Cannot handle the multiple-pickup cycle by normal
resume procedure.
1421 postponed components, restart the production by
selecting Continue"."
Postponed components cannot be placed by selecting
Start from the selected row.""
1422 Canceled the job with components being picked up.
Remove the picked up components to resume
production.
No program step to execute. Pass the PCB through. No program step to execute due to component skip
1423
%s or etc. Check components.
1424 Waiting for Board arrival at %s. Waiting for Board arrival.
1425
1426
Board starts to enter at %s.
Board has arrived at %s.
Just started Board transfer in.
Completed Board transfer in.
1427
Pickup error %m %s-%d3 Head%c1 Nozzle No.%d2
%d7 < %d8 Step:%d5 Offset:%d6
Check status of Head, Component, and Pickup point.
1428
Pickup error (no countermeasure) %m %s-%d3
Head%c1 Nozzle No.%d2 %d7 < %d8 Step:%d5
Choke pressure error Head%c1 Nozzle No.%d2 %d7
1429
> %d8
Nozzle is choked.
1430 Feeder indexing starts.
1431 %s can be set up. Replenish components.
1432 Feeder indexing ends.
1433 %s waits to be unloaded.
1434
1435
Unloading PCB from %s starts.
Unloading PCB from %s is complete.
1436
Coplanarity measurement error %m %s-%d3 Head%c1
Nozzle No.%d2 Step:%d5 Offset:%d6
1437
On-head component is brought back (vision
inspection) %m %s-%d3 Head%c1 Nozzle:%d2
On-head component is brought back (pneumatic
Check the placement point and the nozzle for dirt.
1438 inspection) %m %s-%d3 Head%c1 Nozzle:%d2 %d7 >
Check that the nozzle is not choked. Check the air