2-6 User's Guide For Tape Fe eder Calibration Jig 2.2. Calibration Program S creen Configuration The screen c onfiguration of the calibration jig program is as follows: 1: Major Function Ar ea 2: V ision Ar ea 3: Ou…

2-5
Prepare
2.1.4. Master Feeder
Refers to a reference feeder used to set the origin of a tape feeder.
1: Master Block
2: Clamp Lever
3: 8mm Origin
4: W4P1 Origin
5: Origin greater than 12mm
w Master Block
Block on which the origin of a feeder to be calibrated is marked
Caution
Exercise care not to scratch the top surface of the master
block. If the origin on the top surface of the master feeder is
damaged, the master feeder origin may be distorted.
w Clamp Lever
Lever fixing the master feeder on the feeder base when installing the master feeder
w 8mm/0402 Origin
Origin for calibrating the part pickup position of an 8mm/0402 feeder
w W4P1 Origin
Origin for calibrating the part pickup position of a W4P1 feeder
w Origin Greater than 12mm
Origin for calibrating the part pickup position of an 12mm/16mm feeder

2-6
User's Guide For Tape Feeder Calibration Jig
2.2. Calibration Program Screen Configuration
The screen configuration of the calibration jig program is as follows:
1: Major Function Area
2: Vision Area
3: Output Area
w Major Function Area
§ <0. Jig Setup> Button
Sets the origin of the camera and feeder.
§ <1. Feeder check> Button
Checks the part supply accuracy of the feeder and related problems.
§ <2. Repair> Button
Calibrates a tape feeder.
w Vision Area
Displays menus related to camera and vision setup.
w Output Area
Displays the status of connection between the calibration jig and feeder, camera status,
and mapping result as a message.

3-1
Tape Feeder Calibration
Chapter3. Tape Feeder Calibration
3.1. Flow Chart for Tape Feeder Calibration (Flow Chart)
It is possible to check the part supply accuracy of a feeder by calibrating feeders
periodically and maintaining the feeder in an optimum state.
In particular, when the main board of the tape feeder was replaced, or the index motor,
index gear and sprocket parts were reassembled or replaced, the corresponding feeder
must be calibrated.
The feeder calibration procedure is as follows: