3-25 Tape Feeder Calibration Figure3.4 When Inspection R esult is No t Good w When the inspection result is ’X NG’ Set the eccentric pin of the feed er again referring to the "5.3.3. Adjustment of X Ec centric Pin o…

3-24
User's Guide For Tape Feeder Calibration Jig
Caution
If the feeder hole position recognized by the vision system
is found to be incorrect by clicking the <Grab> button, a
serious problem may occur. Set the origin of the tape feeder
referring to .
4. Once the inspection is completed, the mapping inspection result is displayed.
Figure3.3 When Inspection Result is Good

3-25
Tape Feeder Calibration
Figure3.4 When Inspection Result is Not Good
w When the inspection result is ’X NG’
Set the eccentric pin of the feeder again referring to the "5.3.3. Adjustment of X
Eccentric Pin of Tape Feeder".
w When the inspection result is ’Y NG’
Initialize the sensor referring to "3.4.3. Mapping Inspection" and perform
mapping inspection. If the inspection results are found to be NG more than 2
times, solve the problem referring to "6.1. Problems and Measures".