5-3 Maintenance 5.2.2. Calibration Jig 5.2.2.1. Removal of Foreign Materials on Feeder Base / Ve rtical Plate When the calibrat ion jig has been used, c hec k whether parts or foreign mat erials exist around the feeder b…

5-2
User's Guide For Tape Feeder Calibration Jig
5.2. Calibration Jig
5.2.1. Cautions Regarding Calibration Jig Maintenance
When disassembling the jig cover randomly, internal components may be damaged duo to
incoming microchips or foreign materials and external impact. Use the calibration jig or
perform maintenance with the jig cover being assembled.
Memo
When replacing the service parts, remove the jig cover.
Caution
Do not use the calibration jig with the cover of the area
indicated in the following figure being removed:

5-3
Maintenance
5.2.2. Calibration Jig
5.2.2.1. Removal of Foreign Materials on Feeder Base / Vertical Plate
When the calibration jig has been used, check whether parts or foreign materials exist
around the feeder base. If so, remove them using a brush and air gun referring to the
following figure:
Figure5.1 Removal of Foreign Materials on Feeder Base / Vertical Plate
5.2.2.2. Application of Rust Preventive Oil to Feeder Base / Vertical Plate
Apply rust preventive oil to the feeder base and vertical plate at 6 month intervals referring
to the following figure:
Memo
Recommended rust preventive oil: WD 40 (general commercial item)
Figure5.2 Application of Rust Preventive Oil to Feeder Base / Vertical Plate
1. Unscrew the fixing screw (No. 1) and remove the parts (Nos. 2 and 3) configuring the

5-4
User's Guide For Tape Feeder Calibration Jig
feeder base board.
2. Apply rust preventive oil to the feeder base / vertical plate.
3. After drying the feeder base and vertical plate to which rust preventive oil is applied
for a day, clean the residuals with a clean cloth.
4. Assemble the feeder base board to the calibration jig in the reverse order of
disassembling.
5.3. Tape Feeder
5.3.1. Tape Feeder Inspection
When there is a problem with the part supply accuracy of the tape feeder, inspect the tape
feeder referring to "3.3. Tape Feeder Check".
If feeders are calibrated regularly, it is possible to check feeder problems to secure part
supply accuracy, improving productivity.
5.3.2. Lifetime Management and Overhaul
w 8mm Tape Feeder
If the feeding count of a feeder exceeds 40,000,000, a problem may occur to the
supply accuracy. When the feeding count of a feeder exceeds 40,000,000, inspect the
part supply accuracy of the feeder referring to "3.3.3. Inspection of Part Supply
Accuracy of Feeder".
If the inspection result of the part supply accuracy is 'NG', perform an overhaul of the
feeder. If the inspection result of the part supply accuracy is 'OK', perform an overhaul
of the corresponding feeder after using it until its feeding count becomes 60,000,000.
If feeder overhaul is required, contact our designated C/S company (STS) and local
agent.
w 12mm / 16mm Tape Feeder
If the feeding count of a feeder exceeds 20,000,000, a problem may occur to the
supply accuracy. When the feeding count of a feeder exceeds 20,000,000, inspect the
supply accuracy of the feeder referring to "3.3.3. Inspection of Part Supply Accuracy
of Feeder".
If the inspection result of the part supply accuracy is 'NG', perform an overhaul of the
feeder. If the inspection result of the part supply accuracy is 'OK', perform an overhaul
of the corresponding feeder after using it until its feeding count becomes 30,000,000.
If feeder overhaul is required, contact our designated C/S company (STS) and local
agent.