3-23
Tape Feeder Calibration
Memo
If the vision system fails to recognize the master tape hole, set the
threshold referring to Step 5 in "3.3.3. Inspection of Part Supply
Accuracy of Feeder".
Caution
We are not responsible for defective mapping and part
supply accuracy defects of the feeder due to overuse
(exceeding 150 times of use) of the master tape.
After using the master tape more than 150 times, replace it
without fail.
If the master tape is damaged or deformed, dispose of it
immediately.
3. Perform mapping inspection in the following order:
1) Check whether the hole position is correctly recognized repeatedly by clicking the
<Grab> button 3~5 times. When the origin of the master feeder hole changes in
the vision window, adjust the threshold of the master tape again.
2) Press the <Start Mapping> button to start mapping inspection.
3) When there is existing mapping data, a message confirming whether to perform
mapping inspection appears again. Clicking the <OK> button will delete the
existing mapping data.

3-24
User's Guide For Tape Feeder Calibration Jig
Caution
If the feeder hole position recognized by the vision system
is found to be incorrect by clicking the <Grab> button, a
serious problem may occur. Set the origin of the tape feeder
referring to .
4. Once the inspection is completed, the mapping inspection result is displayed.
Figure3.3 When Inspection Result is Good

3-25
Tape Feeder Calibration
Figure3.4 When Inspection Result is Not Good
w When the inspection result is ’X NG’
Set the eccentric pin of the feeder again referring to the "5.3.3. Adjustment of X
Eccentric Pin of Tape Feeder".
w When the inspection result is ’Y NG’
Initialize the sensor referring to "3.4.3. Mapping Inspection" and perform
mapping inspection. If the inspection results are found to be NG more than 2
times, solve the problem referring to "6.1. Problems and Measures".