SME_Jig_User_Guide(Eng_Ver1).pdf - 第33页

3-1 Tape Feeder Calibration Chapter3. Tape Feeder Calibratio n 3.1. Flow Chart for Tape Feeder C alibration (Flo w Chart) It is possible to check the p art supply accuracy of a feeder by calibrating feeders periodically …

100%1 / 110
2-6
User's Guide For Tape Feeder Calibration Jig
2.2. Calibration Program Screen Configuration
The screen configuration of the calibration jig program is as follows:
1: Major Function Area
2: Vision Area
3: Output Area
w Major Function Area
§ <0. Jig Setup> Button
Sets the origin of the camera and feeder.
§ <1. Feeder check> Button
Checks the part supply accuracy of the feeder and related problems.
§ <2. Repair> Button
Calibrates a tape feeder.
w Vision Area
Displays menus related to camera and vision setup.
w Output Area
Displays the status of connection between the calibration jig and feeder, camera status,
and mapping result as a message.
3-1
Tape Feeder Calibration
Chapter3. Tape Feeder Calibration
3.1. Flow Chart for Tape Feeder Calibration (Flow Chart)
It is possible to check the part supply accuracy of a feeder by calibrating feeders
periodically and maintaining the feeder in an optimum state.
In particular, when the main board of the tape feeder was replaced, or the index motor,
index gear and sprocket parts were reassembled or replaced, the corresponding feeder
must be calibrated.
The feeder calibration procedure is as follows:
3-2
User's Guide For Tape Feeder Calibration Jig
3.2. Jig Setup (Jig Setup)
Perform setup so that the calibration jig camera teaches the origin mark of the master
feeder. The tools required to teach the origin mark of the master feeder are as follows:
w Calibration Jig
w Calibration Software
w Master Feeder
Caution
w If a microchip is on the upper surface of the feeder base when
teaching the origin mark of the master feeder, a calibration error
of +50 ~ +80μm may occur.
w Placing the master feeder with a microchip jammed between the
master feeder and feeder base will make it difficult to check
visually whether a microchip is jammed or not. Therefore, clean
the feeder base before inserting feeders.
w For more details about calibration jig cleaning, refer to ”5.2.2.1.
Removal of Foreign Materials on Feeder Base / Vertical Plate”.
Remove any foreign materials on the master feeder and feeder
base using a brush or air gun.
The method to teach the origin mark of the master feeder is as follows:
1. Turn on the power supply to the calibration jig.
2. Insert the master feeder into the feeder base slot according to the type of feeders whose
origin is to be set.
1: Left (#1) Slot
2: Right (#2) Slot