Maintenance
5.6. Feeder Base Board Replacement
It is recommended to replace the feeder base board after installing and removing the feeder
on/from the feeder base slot 10,000 times. When the feeder installation/removal count
exceeds 10,000, problems with feeder communication and the power supply may occur
depending on the customers' operation environment. Replace the feeder base board
referring to the following figure:
1. Remove 4 sets of bolts fixing the feeder base board using a crosshead (Phillips)
screwdriver.
2. Remove one bolt fixing the tie mount using a crosshead (Phillips) screwdriver.

5-12
User's Guide For Tape Feeder Calibration Jig
3. Disconnect the cable connector and feeder base board. When disconnecting the cable,
disconnect the cable while holding the entire cable so that the connector will not be
damaged.
4. After replacing the feeder base board with a new one, assemble it in the reverse order
of disassembling.
Memo
w Feeder Base Board Name: FEEDER BASE BOARD 1 SLOT
w Feeder Base Board Number: EP16-002162A

5-13
Maintenance
5.7. Change the Fuse
'If overcurrent flows to the calibration jig, the power supply fuse will be cut off. If it does,
replace the fuse referring to the following:
1. Turn off the power switch of the calibration jig and remove the power cable from the
calibration jig.
2. Place the calibration jig on a flat surface with the power switch facing upward.