2.7 Verification of Current Pattern Program Data 2.7 . 3 Operation for Confirmation It is advisable that performance of the X / Y table be tested before starting automatic operation according to the selected pattern prog…

2.7
Verification
of
Current
Pattern
Program
Data
2.7
.
2
X
/
Y
Table
Test
at
P
.
E
.
C
.
Position
[
Function
]
This
function
enables
the
activation
of
only
the
X
/
Y
table
according
to
the
pattern
program
data
of
the
current
production
program
.
Components
are
not
placed
.
Refer
to
“
3.4
.
1
X
/
Y
Table
Test
”
in
the
instruction
manual
(
SECTION
K
MAINTENANCE
MANUAL
)
for
details
.
Procedure
(
1
)
Turn
on
the
“
P
.
E
_
C
.
RECOG
LIGHT
”
switch
on
the
front
console
panel
and
then
turn
off
the
“
LIGHT
”
switch
.
(
2
)
Place
a
P
.
C
.
B
.
on
the
X
/
Y
table
and
perform
the
X
/
Y
table
test
at
the
P
.
E
.
C
.
camera
position
.
Then
,
confirm
the
following
items
.
①
Check
whether
or
not
components
match
with
the
patterns
on
the
P
.
C
.
B
.
If
not
,
take
necessary
measures
such
as
correcting
the
pattern
program
data
.
②
Check
that
the
nozzle
does
not
place
components
on
areas
other
than
the
patterns
on
the
P
.
C
.
B
.
The
center
of
the
cross
line
on
the
monitor
shows
the
spot
where
a
component
should
be
placed
by
the
vacuum
nozzle
.
vacuum
2
一
28
9
R
03
-
001
ACP
01
EOP
2
-
28

2.7
Verification
of
Current
Pattern
Program
Data
2.7
.
3
Operation
for
Confirmation
It
is
advisable
that
performance
of
the
X
/
Y
table
be
tested
before
starting
automatic
operation
according
to
the
selected
pattern
program
data
.
•
Although
,
the
machine
does
not
place
any
components
during
X
/
Y
table
test
operation
,
fundamental
errors
can
be
found
in
the
selected
pattern
program
data
.
2.7
.
4
Actual
Component
Placement
Test
Check
whether
or
not
the
machine
can
place
actual
components
on
a
P
.
C
.
B
.
without
hindrance
.
Refer
to
“
2.9
Starting
,
Emergency
Stop
and
Temporary
Stop
(
Pause
)
Operations
for
Automatic
Operation
(
“
PLACE
”
Mode
)
”
for
details
of
test
and
check
procedure
.
Procedure
for
X
/
Y
Table
Test
•
Position
a
P
.
C
.
B
.
on
the
X
/
Y
table
.
•
Press
the
[
ZERO
]
button
.
Each
device
is
zeroed
.
•
Open
the
“
X
/
Y
TABLE
TEST
”
display
.
(
Hierarchical
Sequence
:
“
SPECIAL
SEL
.
”
Display
—
“
DEVICE
TEST
”
Display
—
“
X
/
Y
TABLE
TEST
”
Display
)
•
Set
parameters
in
the
text
boxes
of
the
labels
“
X
/
Y
TABLE
’
S
LOCATION
MODE
”
and
“
OPERATION
MODE
”
at
the
“
X
/
Y
TABLE
TEST
”
display
.
•
Press
the
[
MOVE
]
button
.
The
X
/
Y
table
test
is
implemented
.
Note
:
Refer
to
“
3.4
.
1
X
/
Y
Table
Test
”
in
the
instruction
manual
(
SECTION
皿
MAINTENANCE
MANUAL
)
for
details
.
Ref
.
:
When
P
.
C
.
B
.
’
s
produced
based
on
newly
created
pattern
program
data
and
component
library
data
,
it
is
recommended
that
not
only
X
/
Y
table
test
be
implemented
but
also
P
.
E
.
C
.
and
component
recognition
tests
.
Refer
to
items
“
3.4
.
2
P
.
E
.
C
Recognition
Test
”
and
“
3.4
.
3
Component
Recognition
Test
”
in
the
instruction
manual
(
SECTION
瓜
MAINTENANCE
MANUAL
)
for
details
.
are
2
—
29
QRo
^
-
nm
ACP
01
EOP
2
-
29

2.8
Setting
of
Operation
Mode
2.8
Setting
of
Operation
Mode
Follow
the
procedure
described
in
“
2.8
.
1
”
through
“
2.8
.
8
”
before
starting
the
automatic
operation
(
“
PLACE
”
Mode
)
.
Refer
to
“
4.6
Operation
Mode
”
for
details
.
2.8
.
1
Automatic
Feeder
Axis
Adjustment
Mode
Refer
to
“
4.6
.
1
AUTOMATIC
FEEDER
AXIS
ADJ
.
MODE
”
for
details
.
2.8
.
2
Overall
Tact
Time
Reduction
Refer
to
“
4.6
.
2
OVERALL
TACT
TIME
REDUCTION
”
for
details
.
2.8
.
3
Shortage
of
Component
Detection
Mode
Refer
to
“
3.5
Component
Shortage
Detection
Function
”
and
“
4.6
.
3
SHORTAGE
OF
COMP
.
DETECTION
MODE
”
for
details
.
2.8
.
4
Alternate
Mode
Refer
to
“
3.7
Alternate
Mode
”
and
“
4.6
.
4
ALTERNATE
MODE
”
for
details
.
2.8
.
5
Recovery
Mode
Refer
to
“
3.6
Automatic
Recovery
Function
”
and
“
4.6
.
5
RECOVERY
MODE
”
for
details
.
2.8
.
6
Feeder
Carriage
Axis
Mode
Refer
to
“
4.6
.
6
FEEDER
CARRIAGE
AXIS
MODE
”
for
details
.
2.8
.
7
X
/
Y
Table
Axis
Mode
Refer
to
“
4.6
.
7
X
/
Y
TABLE
AXIS
MODE
”
for
details
.
2.8
.
8
Trash
Box
Fill
Up
Warning
Mode
Refer
to
“
4.6
.
8
Setting
of
Trash
Box
Fill
-
Up
Warning
Mode
”
for
details
.
2
-
3 0
QRO
^
-
nm
ACP
01
EOP
2
-
30