3_AVS-V2_MCT-UM-internal_EN_07-2019.pdf - 第117页

ASM AVS - U SER M ANUAL P AGE 117 OF 182 Sing le Valu e c hart for t he w hole MCT : The pri nter mo de „ Acc ulum ate“ is also us ed to sh ow a sin gle valu e c hart with all m eas - urem ent poi nts a nd to l ist t hi …

100%1 / 182
ASM AVS - USER MANUAL
PAGE 116 OF 182
The 4 measurements are evaluated in the printer mode Accumulate“.
Additionally filter the measurements for the printing direction to get the values for each
direction separately, because these are the values you must enter in the printing machine.
To decide which of the two values (median, mean) to use for the correction, you need to
look at the result in the "frequency" chart (Gaussian bell curve).
If it is a normal distribution, use the MEAN.
If it is not a normal distribution, use the MEDIAN.
Normal distributed, use MEAN Not normal distributed, use MEDIAN
Adjusting the correction values on the printer, see 7.2 Corrections of Offset values on DEK
printers.
ASM AVS - USER MANUAL
PAGE 117 OF 182
Single Value chart for the whole MCT:
The printer mode Acculumate“ is also used to show a single value chart with all meas-
urement points and to list this chart in the report.
The statistics cannot be considered here, since in such evaluation, the stencil quality influ-
ences the measuring result.
- Printer mode Point2Point”:
As already described in 5.2.25.1, the capability of a printer cannot be analyzed with one
board, because 1 board means only one time executing the printing process.
For a printer MCT, many boards, means many measurements (min. 20), must be carried
out and analyzed together in 1 calculation.
This is the Point2Point” calculation.
On the Point2Pointcalculation, the X- and Y- Offsets of the single measurement points,
over the number of selected measurements are being evaluated regarding standard devia-
tion and mean.
The average of all these standard deviation and mean values is being calculated and the
cm and cmk values are determined.
This is also, to take out the Quality of a Stencil from the assessment.
Example:
In a template with 7x4 measurement points, so the standard deviation and the mean value
is calculated with 28 points over 20 measurements.
Subsequently, the average is taken from these 28 standard deviations and the 28 mean
values and thus determines the Cm and Cmk.
The ”number of Valid:”
means the number of
boards in case of
Point2Point mode.
ASM AVS - USER MANUAL
PAGE 118 OF 182
6. Result area
a. Recipe:
This shows the recipe (measure plan) as an image, which is used in the project.
This is the only tab which is not depending on the filter settings above.
b. Scan:
This view is only active in the printer mode “Single”!
The evaluation is the same as with placement machines.
See also b Scan:
c. Scan 3D:
This view is only active in the printer mode “Single”!
The evaluation is the same as with placement machines.
See also c. Scan 3D:
d. Statistics:
Show the mathematical result of the selected measurement(s), depending on the filter
settings above.
The ”number of Valid:”
means the number of
boards in case of
Point2Point mode.