3_AVS-V2_MCT-UM-internal_EN_07-2019.pdf - 第87页

ASM AVS - U SER M ANUAL P AGE 87 OF 182 5.2.24.1.3 New Project - Recipe In thi s ste p, y ou m ust selec t t he re cipe t hat i s to be u se d to per form the m easu rem ent. (1) Re cip e sel ecti on: The co nten t of th…

100%1 / 182
ASM AVS - USER MANUAL
PAGE 86 OF 182
5.2.24.1.2 New Project Machine
In these view two important settings has to be configured.
(1) Transport Lane:
Only in case of a double conveyor, you must select, either this project covers the
measurement of conveyor lane 1, conveyor lane 2, or both.
(2) Head and Camera:
In the right area of the window you must configure, which head/camera combination you
want to measure with this project.
If you select the checkbox with the camera name, all the other checkboxes in the chain
up to the gantry are automatically checked too.
(3) Measure Mode:
Description of “Measure Mode” see 5.2.18.12 (6).
The Recipe List on the next page is automatically filtered by that parameter, since this is
a significant parameter for the Recipe description.
ASM AVS - USER MANUAL
PAGE 87 OF 182
5.2.24.1.3 New Project - Recipe
In this step, you must select the recipe that is to be used to perform the measurement.
(1) Recipe selection:
The content of the list is depending on the filter settings on top of the list, as well as on
the Measure Mode set in the Machine Tab.
You can reduce the content by setting the filters.
Highlight a line, to see the recipe details below the list.
To select a recipe for using in the project, activate the checkbox on the left end of the
line. If you activate the checkbox for a recipe, this recipe is assigned to the project.
If a recipe was already selected before, the software asks you for changing the assign-
ment!
(2) Details and information:
In this area you find a detailed description of the recipe which is highlighted above.
You can also read the information about the required setup and PCB data in Siplace Pro,
which you must schedule to the line.
List of valid recipes.
Filter for Recipes, to reduce the list
below. The list is already filtered
completely by default. Deselect
single filters to expand the list.
Select the Board that you
use for the measurement.
Item, Gantry, group
assignment!
Recipe Details
ASM AVS - USER MANUAL
PAGE 88 OF 182
(3) Select Glassplate:
You have to choose a glass board that you want to use in the project.
This is, to close the loop regarding calibration data.
Each glass board must have a valid calibration certificate, as well as the AVS device.
In the drop down list you will only see the boards that are defined (connected) to the de-
vice you are working on.
It is also possible to choose 2 glass plates if 2 plates were used in the project.
(4) Item Configuration:
Once you have selected a recipe for the project, you must assign the items, gantries,
groups, ….
Check if the Item name (link to SIPLACE Pro) is linked to the correct group and specifica-
tion values.
If this is not the case, you can change the group number (1
st
column).
- Assign the “Group” number to the corresponding Gantry.
If you Click onto a Group number, you can change the value to the required group,
via the drop-down list.
- Select the Checkbox in the “Angle” column, if you want to measure the angle on the
corresponding head.
In this view you can also change the Specification values, if you like to use different specifica-
tions in the project.
WARNING
2T! Wrong interpretation possible !
When the placement program is scheduled via Siplace Pro or the Linux line computer, you must always
make sure that the above assignment of items and groups to the relevant placement heads corresponds to
the reality!
[Serial-No.] [production date]