3_AVS-V2_MCT-UM-internal_EN_07-2019.pdf - 第77页

ASM AVS - U SER M ANUAL P AGE 77 OF 182 5.2.18.17 Base Data – User Jobs In Contact Data 5.2.17 Cu rren t Co ntac ts you can sele ct Job descriptions o ut of a l ist. This list is coming fr om the BaseDa ta – User Jobs ta…

100%1 / 182
ASM AVS - USER MANUAL
PAGE 76 OF 182
Details on Reference data:
Because of the material used and the mechanical structure of a printer stencil, it cannot be
considered as a certified measuring instrument.
The accuracy of the positions and size of the holes is too small, so they represent a major ef-
fect on a single measurement.
For this reason, a "Point2Point" calculation is carried out for the MCT.
But to basically bring the readings on a better measure, namely already for the adjustment,
correction data are used for the stencil.
If the checkbox "correction data" is enabled, the values are subtracted directly from the
measured values.
Although now, each individual measurement is reflecting the print quality and the stencil
quality is already calculated out of the result, a Board2Board measurement or a calculation
Point2Point must be performed, to determine the repeatability (printers MCT).
Because due to the materials used, a reliable stability or validity of the correction values is
not ensured.
5.2.18.16 Base Data Default Countries
In the structure tree, you can add countries. Therefore, these countries must be available in
the database.
If you miss a country which you plan to add to the tree, you need to add the country to de-
fault countries base data first! See 5.2.14
ASM AVS - USER MANUAL
PAGE 77 OF 182
5.2.18.17 Base Data User Jobs
In Contact Data 5.2.17 Current Contacts you can select Job descriptions out of a list.
This list is coming from the BaseData User Jobs table.
Double Click the User Job you want to change or mark the line and press “Edit” to open the
“User Job Details” view.
Press “New” if you want to add another User Job into the database.
5.2.19 Base Data - Capability of measuring equipment
All Information regarding measuring capability of the AVS equipment you find in the manual
4_AVS-V2_Certification_EN_MM-YYYY.
ASM AVS - USER MANUAL
PAGE 78 OF 182
5.2.20 Base Data Import/Export
This function is to get a view of the history of Import and Export jobs to the AVS Database. In-
formation about the data structure, see 2_AVS-V2_Software Installation_EN_MM-YYYY.
In the window appearing, you can see each Import Export documented.
5.2.21 Base Data Placement Force Measurement
All Information to placement force measurement with the AVS Software, you can find in
6_AVS_V2_FMT_UM-internal_EN_MM-YYYY .