ASM AVS - U SER M ANUAL P AGE 140 OF 182 5.3.5.2 Components (Items) Aft er the glas s bo ard for the rec ipe w as c hosen li ke d esc ribe d in 4 .3.5 .1 , in the next ste p com - pon ents (I tems) can be sele cte d . Th…

100%1 / 182
ASM AVS - USER MANUAL
PAGE 139 OF 182
Now the register mark has to be described (teached).
The camera is above the register mark!
Click the button »Register Mark« in the area »Edit Model«.
The Siplace Vision Software for fiducials will be opened
Now you can teach (e.g. using the »wizard«) the fiducial like known in the SIPLACE Vision
software.
You will be asked whether you want to use the fiducial in your recipe when
you leave the SIPLACE Vison Software
5.3.5.1.3 Save a board as a template.
You can save a board, which you have created or edited, as a template.
So you are able to load this board into another recipe as described in 4.3.5.1 Change glass board
/ describe new
You have made all settings as described in 4.3.5.1.1 Global fiducials and 4.3.5.1.2 Local fidu-
cials (register marks)!
Click now on »Save Page« to save the board in the preselected directory, via windows »save
as« dialog.
ASM AVS - USER MANUAL
PAGE 140 OF 182
5.3.5.2 Components (Items)
After the glass board for the recipe was chosen like described in 4.3.5.1, in the next step com-
ponents (Items) can be selected.
Therefor switch to partial view »2D Items«.
The list shows all components (Items) added to the recipe.
At the description of items, in principle, you distinguish between »Componenand »task«
Under »Component« you understand the component itself.
The component together with the surrounding register marks is named »Task«
NOTICE
Generally speaking:
»Item« always means the »Task«, as a description of the measuring process.
In case you want to add a component, either you can create a new one or you can load an exist-
ing component into the recipe.
Name of item can be
changed
Create new item
Load available item
into recipe.
Edit task
(Measuring Step)
Save of loaded task
Edit the com-
ponent
Delete component
from the list
ASM AVS - USER MANUAL
PAGE 141 OF 182
5.3.5.2.1 Create new component
Click on button »New« in the group task
A »Windows« dialog appears and you can choose between 3 different
versions.
The component can be renamed afterwards. Use the emty field
After you have select the »Task« version, you can teach the component with
the »Siplace Visiosoftware
5.3.5.2.2 Teaching components
Ensure that the camera is centered above the middle of a component.
If you work on a »Quadruple measurement Item«, place the camera over an edge of the
component.
See 4.3.5.1.1!
Click on »Edit« in the group »Component« and edit the component like a fiducial in Siplace
Vision
Only for selftest (dummy)
Four times measurement!
For components >3mm
Single measurement!
For components < 3mm
Four times
measurement
Single
measurement