1.4.3 Cleaning of V acuum Nozzle Periodically perform cleaning of vacuum nozzles to maintain reliable and stable component picks and placement. • It is advisable that the nozzle be cleaned at least once a week. • Change …

1.4.2 Filter Replacement of Head Section
(1) Detachment of Filter Holder
Pull out the filter holder forward.
Fig. 4A61
(2) Replacement of Filters
Detach two filters sideways and replace them with new ones.
Fig. 4A62
(3) Attachment of Filter Holder
Direct Cut-Off Side D upward and insert the filter holder fully until it
stops.
0305-001 1-49 AIL01ETRP
1.4 Maintenance Method

1.4.3 Cleaning of Vacuum Nozzle
Periodically perform cleaning of vacuum nozzles to maintain reliable
and stable component picks and placement.
• It is advisable that the nozzle be cleaned at least once a week.
• Change cleaning frequency according to varying frequency of use
and stain degree along with certain environmental conditions.
• When the vacuum suction force weakens or a nozzle failure in com-
ponent pick or placement occurs, it is required to check the stain
degree and clean the nozzle.
Fig. 4A63
Cleaning Method
(1) Detach the vacuum nozzle.
(2) Blow air to remove dust and dirt. At this time, use clean, dry, and
non-lubricated air.
When the nozzle is heavily stained, clean it with an ultrasonic
cleaning machine or a rag soaked in alcohol.
(3) Attach the vacuum nozzle.
(a) Refer to "1.4.4 Detachment and Attachment of Vacuum
Nozzle" for detailed information of detachment and
attachment procedures.
(b) Detach the nozzle before demagnetizing it.
Keep the head section free of any magnetic field.
As an example,
• Do not bring a magnet close to the head section.
• Do not bring the demagnetizer to the head section.
0409-002 1-50 AIL01ETRP
1.4 Maintenance Method
Note

0409-001 1-50-1 AIL01ETRP
1.4 Maintenance Method
Note
Bolt (4-M3×20)
φ3.2
15 15 15 15 15
20
3
75
15 15 15 15 15
75
Material: A5052
5
5
5
5
5
5
5
5
Unit: mm
Bolt (4-M3×20)
Ultrasonic Cleaning Method
• Set the nozzles in a nozzle cleaning jig as one shown in the figure
below and dip the jig low in the ultrasonic cleaner filled with water.
Keep it in the jig for approximately 15 minutes for the cleaning.
The nozzle cleaning jig must be prepared on the customer
side.
• After washing with the ultrasonic cleaner, blow air to the nozzles.
When the nozzles are not dry enough, wipe them with a rag.
(Whole View)
(Bottom View)
Fig. 4A63-1 Nozzle Cleaning Jig(Example)