Error ID ltem Description
630206 Nozzle Bypass Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master level in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
630207 Nozzle Bypass Nozzle Drop
(Cause 1) The nozzle being used has dropped.
(Remedy 1) Check the pertinent nozzle.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
630208 Nozzle Bypass Dummy Nozzle
630209 Nozzle Bypass Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the "Head/Noz. Bypass" tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
63020a Nozzle Bypass Nozzle Change Error. (Cam lock action)
63020b Nozzle Bypass Nozzle Change Error. (Cam Free action)
63020c Nozzle Bypass Cam Origin Error.
63020d Nozzle Bypass Nozzle Teach Error.
63020e Nozzle Bypass Nozzle Posture Detection
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-138 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
630301 Head Skip Communication Error
630302 Head Skip Head Origin
630303 Head Skip Overtime Head Origin Return
630304 Head Skip Unselected Nozzle Drop
630305 Head Skip Dummy Nozzle
630306 Head Skip Manual Bypass
630307 Head Skip Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
630401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
630402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
630403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
630404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
630501 Master Head Offset Linear Measure System Was At High Position.
630502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-139 AIL01ETRP
3.3 Error IDs and Remedial Procedures
0511-002 2-140 AIL01ETRP
Error ID ltem Description
630601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
630701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
630702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
630801 Recog. Data Teach Recognition Error Code
630901 Trash Teach Error Code. Recognition Error Code
630b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.