4OM-1003-007.pdf - 第26页

Safe-15 AIL01E-P Safety Precautions Œx••‚Æ•\•¦‚³‚ê‚Ä‚¢‚é‚à‚Ì 0412-001 3. Safety-Related Functions Safety Switches When an error is detected in the machine, the safety switches are designed to stop the dangerous moving me…

100%1 / 409
Safe-14 AIL01E-P
Safety Precautions
0412-001
Notes on Maintenance
WARNING
Only qualified personnel should perform the maintenance work
carefully for the machine in compliance with the specified
instructions.
Before the maintenance work, be sure to turn off the power
breaker and the air source and lock them with padlocks.
Power Breaker: Set the power breaker to the "OFF" side and
lock it with a padlock.
Air Source : Stop the air supply and set the main valve to
the "EXH." side. After that, be sure to lock it
with a padlock.
Designate a person who can have charge of the padlock key.
If the provided padlock is lost or damaged, purchase its
substitute.
Residual voltages may remain behind for a few minutes in the
internal devices of the machine after power interception.
Touch the internal devices carefully. Otherwise, electric shock
can result from direct contact with live conductors.
Safe-15 AIL01E-P
Safety Precautions
Œx••‚Æ•\•¦‚³‚ê‚Ä‚¢‚é‚à‚Ì
0412-001
3. Safety-Related Functions
Safety Switches
When an error is detected in the machine, the safety switches are designed to stop the
dangerous moving mechanisms of the machine. Everything is processed on the machine
side (hardware) without using any software application on the computer side.
[EMERGENCY STOP] Switches
Press one of the [EMERGENCY STOP] switches to immediately stop the machine in an
emergency. The power is turned off and the machine stops immediately.
[EMERGENCY STOP]
Switch (1)
[EMERGENCY STOP]
Switch (2)
[EMERGENCY STOP]
Switch (4)
[EMERGENCY STOP]
Switch (3)
Fig. 1X13 Front View
Fig. 1X14 Rear View
Fig. 1X15 [EMERGENCY STOP] Switch
Safe-16 AIL01E-P
Safety Precautions
Table 1X1
Switch Name Countermeasures
[EMERGENCY STOP] Switch (1)
[EMERGENCY STOP] Switch (2)
[EMERGENCY STOP] Switch (3)
[EMERGENCY STOP] Switch (4)
Pressing one of the [EMERGENCY STOP] switches
cuts power to the following modules.
All power sources for loads are shut off.
The power supply to the mechanisms of all motor
shafts and 24-voltage loads in the solenoid system
(SOL and SV) is shut off.
Note: The load power supply for the vacuum
pump and the DD motor is excluded. The
control power supply for the control boards
and sensors is also excluded.
0412-001