4OM-1003-007.pdf - 第233页

Error ID Item Description 050401 T able-X Axis Limit (+) Limit error has been detected. 050402 T able-X Axis Limit (-) Limit error has been detected. (Cause 1) An optical beam of the sensor is shielded. (Cause 2) Dirt ad…

100%1 / 409
(05 Table X)
Error ID Item Description
050101 Table-X Axis Origin Encoder origin was not detected.
(Cause 1) The encoder section of the motor may be defective or the encoder cable may be
broken.
(Remedy 1) Turn off the power and check for looseness of the connector section for the signal
cable.
If the error is not canceled yet after this check operation, the broken signal cable
or the motor may be defective. Consult our service personnel for the remedy.
050102 Table-X Axis Origin Origin sensor (slide) was not detected.
(Cause 1) The sensor may be defective or the cable may be broken.
(Remedy 1) Press the [RETURN] button to cancel the error display and then the [ALL] button
entitled "ZERO".
If the error cannot be canceled after the zeroing operation, it is required to re-
place the sensor or the sensor cable with a new one. Consult our service person-
nel for details.
050103 Table-X Axis Origin Origin sensor (slide) and Limit error has been detected.
050104 Table-X Axis Origin Feedback value is indefinite.
050105 Table-X Axis Origin The component pick-up (z) axis is not at origin.
050201 Table-X Axis Timing Task has not been completed unable to continue.
050301 Table-X Axis Data The driver data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per
sonnel for the remedy.
0511-002 2-52 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
050401 Table-X Axis Limit (+) Limit error has been detected.
050402 Table-X Axis Limit (-) Limit error has been detected.
(Cause 1) An optical beam of the sensor is shielded.
(Cause 2) Dirt adheres to the sensor and the optical beam is shielded.
(Remedy 1) Turn off the power supply and move the X/Y table to the position where opera
tions can be performed more easily.
Re-attach the light shield plate and the sensor securely (remove the looseness).
Re-supply power to the machine and perform the zeroing operation.
(Remedy 2) Wipe off dirt on the sensor and re-perform the zeroing operation.
050502 Table-X Axis Servo Alarm User constant breakdown.
[Shutdown touch sw key and mainbreaker sw off.]
050503 Table-X Axis Servo Alarm Main circuit encoder error
050504 Table-X Axis Servo Alarm User constant setting error.
[Shutdown touch sw key and mainbreaker sw off.]
050505 Table-X Axis Servo Alarm Combination error
050509 Table-X Axis Servo Alarm Dividing ratio setting error.
[Shutdown touch sw key and mainbreaker sw off.]
05050a Table-X Axis Servo Alarm Encoder model unmatched.
[Shutdown touch sw key and mainbreaker sw off.]
050510 Table-X Axis Servo Alarm Overcurrent or Heat Sink Overheated.
[Shutdown touch sw key and mainbreaker sw off.]
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-002 2-53 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
050530 Table-X Axis Servo Alarm Regeneration error detected
050532 Table-X Axis Servo Alarm Regenerative overload
050533 Table-X Axis Servo Alarm Main circuit power supply wiring error
050540 Table-X Axis Servo Alarm Overvoltage
050541 Table-X Axis Servo Alarm Undervoltage
050551 Table-X Axis Servo Alarm Overspeed
050571 Table-X Axis Servo Alarm Overload: high load
050572 Table-X Axis Servo Alarm Overload: low load
050573 Table-X Axis Servo Alarm Dynamic break overload
050574 Table-X Axis Servo Alarm Overload of Surge Current Limit Resistor
05057a Table-X Axis Servo Alarm Heat sink overheated
050581 Table-X Axis Servo Alarm Encoder backup error.
[Shutdown touch sw key and mainbreaker sw off.]
050582 Table-X Axis Servo Alarm Encoder checksum error.
[Shutdown touch sw key and mainbreaker sw off.]
050583 Table-X Axis Servo Alarm Absolute encoder battery error
050584 Table-X Axis Servo Alarm Encoder data error.
[Shutdown touch sw key and mainbreaker sw off.]
050585 Table-X Axis Servo Alarm Encoder overspeed
050586 Table-X Axis Servo Alarm Encoder overheated
0505b1 Table-X Axis Servo Alarm Reference speed input read error
0505b2 Table-X Axis Servo Alarm Reference torque input read error
0505b3 Table-X Axis Servo Alarm Current detection error
0505b6 Table-X Axis Servo Alarm Gatearay error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-002 2-54 AIL01ETRP