4OM-1003-007.pdf - 第332页
Error ID ltem Description 610601 Head Origin Offset T otal Designate Loop Exceeded Time. (Cause 1) Each head deviated from its origin position in comparison with the master head. (Remedy 1) Check if the master head is no…

Error ID ltem Description
610301 Head Bypass Communication Error
610302 Head Bypass Head Origin
610303 Head Bypass Overtime Head Origin Return
610304 Head Bypass Unselected Nozzle Drop
610305 Head Bypass Dummy Nozzle
610306 Head Bypass Manual Bypass
610307 Head Bypass Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
610401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
610402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
610403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
610404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
610501 Master Head Offset Linear Masure System Was At High Position.
610502 Master Head Offset Linear Masure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0403-002 2-131 AIL01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
610601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
610701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
610702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
610801 Recog. Data Teach Recognition Error Code.
610901 Trash Teach Error Code. Recognition Error Code.
610a01 Gain Level Teach Error Recognition Error Code.
610b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures
0511-002 2-132 AIL01ETRP

(62 Nozzle Level)
Error ID ltem Description
620101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
620201 Nozzle Bypass Nozzle Down Error (L)
620202 Nozzle Bypass Nozzle Down Error (H)
620203 Nozzle Bypass Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
620204 Nozzle Bypass Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
620205 Nozzle Bypass Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
0511-003 2-133 AIL01ETRP
3.3 Error IDs and Remedial Procedures