4OM-1003-007.pdf - 第271页

(0f P .C.B. T ransfer) Error ID Item Description 0f0101 Transfer Origin Output signal from the pulse motor driver was not detected. 0f0102 Transfer Origin Lower limit of x/y table chute was not detected. ; ls15/PHS61 0f0…

100%1 / 409
Error ID Item Description
0e0201 Camera-Y Axis Timing Task has not been completed unable to continue.
0e0301 Camera-Y Axis Data The driver data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0e0401 Camera-Y Axis Limit Limit error has been detected. ; BPH5 E/NR
0e0402 Camera-Y Axis Limit Limit error has been detected. ; BPH6 E/NR
(Cause 1) When Camera Y was activated, the optical beam of the sensor was shielded.
(Remedy 1) Press the [RETURN] button to cancel the error display and remove the cause of
the error.
Zero all axes and re-start the operation.
0e0601 Camera-Y Axis Communication Controller incomplete resulting in an overtime alarm.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-002 2-80 AIL01ETRP
3.3 Error IDs and Remedial Procedures
(0f P.C.B. Transfer)
Error ID Item Description
0f0101 Transfer Origin Output signal from the pulse motor driver was not detected.
0f0102 Transfer Origin Lower limit of x/y table chute was not detected. ; ls15/PHS61
0f0103 Transfer Origin Upper limit of x/y table chute was not detected.
; BPH60 E/NR
0f0104 Transfer Origin Lower limit of transfer was not detected. ; BPH40 E/NR
0f0105 Transfer Origin Upper limit of transfer was not detected. ; BPS1
0f0106 Transfer Origin P.C.B. transfer was not at stop position.
0f0107 Transfer Origin The transfer was not completely zero during the set time.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0f0201 Transfer Timing Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0f0301 Transfer Data The driver data was detected outside of the possible range.
0f0302 Transfer Data The driver data was error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-002 2-81 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
0f0401 Transfer Limit Limit error has been detected. ;BPH36 E/NR
0f0402 Transfer Limit Limit error has been detected. ;BPH37 E/NR
(Cause 1) The emitted optical beam was not received by the sensor or the light shield plate.
Dirt adheres to the light shield plate and an optical beam of the sensor is shielded.
(Remedy 1) Press the [RETURN] button to cancel the error display, open the front cover, and
check the P.C.B. transfer operation through manual step operation.
Remove the cause due to which the emitted optical beam was not received by
the sensor or the light shield plate.
Zero the P.C.B. transfer again.
0f0501 Transfer Overload Overload has been detected. ;BPH38/BPH71 E/NR
(Cause 1) The timing belt was trapped by something during P.C.B. transfer operation and got
loose, shielding the optical beam emitted from the sensor.
(Remedy 1) Press the [RETURN] button to cancel the error display and remove the cause
due to which the timing belt was trapped. Then, zero the P.C.B. transfer.
0f0601 Transfer P.C.B. Detection The P.C.B. has not passed from the input conveyor into
table chute.
(Cause 1) The P.C.B. detection photosensor of the transfer conveyor detects a P.C.B. all the
time during P.C.B. transfer operation. (The P.C.B. is not transferred.)
(Remedy 1) Press the [RETURN] button to cancel the error display and remove the cause
due to which the P.C.B. is not transferred.
When the sensitivity of the sensor is too high, decrease the sensitivity.
Adjust the sensor position when it is not correct.
0f0602 Transfer P.C.B. Detection The P.C.B. has not passed from the table chute into the
output conveyor.
0f0603 Transfer P.C.B. Detection The P.C.B. has not passed from the input conveyor into table
chute. (The P.C.B. disappeared.)
0f0604 Transfer P.C.B. Detection The P.C.B. has not passed from the input conveyor into table
chute. (P.C.B. was taken on x/y table chute.)
0f0605 Transfer P.C.B. Detection The P.C.B. has not passed from the input conveyor into table
chute. (P.C.B. on input conveyor was not able to move to its
outlet.)
(Cause 1) An error was detected during P.C.B. transfer.
(Remedy 1) Press the [RETURN] button to cancel the error display and remove the cause of
the error.
0511-002 2-82 AIL01ETRP
3.3 Error IDs and Remedial Procedures