Error ID ltem Description 660301 Head Skip Communication Error 660302 Head Skip Head Origin 660303 Head Skip Overtime Head Origin Return 660304 Head Skip Unselected Nozzle Drop 660305 Head Skip Dummy Nozzle 660306 Head S…

100%1 / 409
Error ID ltem Description
660206 Nozzle Bypass Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master nozzle in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
660207 Nozzle Bypass Nozzle Drop
(Cause 1) The nozzle being used has dropped.
(Remedy 1) Check the pertinent nozzle.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
660208 Nozzle Bypass Dummy Nozzle
660209 Nozzle Bypass Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the “Head/Noz. Bypass" tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
66020a Nozzle Bypass Nozzle Change Error. (Cam lock action)
66020b Nozzle Bypass Nozzle Change Error. (Cam Free action)
66020c Nozzle Bypass Cam Origin Error.
66020d Nozzle Bypass Nozzle Teach Error.
66020e Nozzle Bypass Nozzle Posture Detection
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0511-003 2-150 AIL01ETRP
Error ID ltem Description
660301 Head Skip Communication Error
660302 Head Skip Head Origin
660303 Head Skip Overtime Head Origin Return
660304 Head Skip Unselected Nozzle Drop
660305 Head Skip Dummy Nozzle
660306 Head Skip Manual Bypass
660307 Head Skip Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
660401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
660402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
660403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
660404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
660501 Master Head Offset Linear Measure System Was At High Position.
660502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
3.3 Error IDs and Remedial Procedures
0305-001 2-151 AIL01ETRP
Error ID ltem Description
660601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
660701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
660702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
660801 Recog. Data Teach Recognition Error Code.
660901 Trash Teach Trash Teach Error Code.
660b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures