4OM-1003-007.pdf - 第377页
Recognition Error ID Recognition Error Contents, Cause, and Remedy 02**2200** Error in Lead Inspection 02**2201** The number of leads is incorrect. 02**2202** The number of leads is small. 02**2203** The number of leads …

(a) Error IDs "*" will be filled with primary error classification
and detail codes.
(b) When an error ID other than the described ones is issued,
contact our service personnel for some advice.
Table 4B15
Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**1000** Component Missing
02**1001** Component was not picked up by nozzle.
(Cause 1)The feeder carriage is loaded with a feeder that contains components
different from the specified ones.
(Cause 2)The vacuum suction force is too weak.
(Cause 3)An improper nozzle is selected for the components or vice versa.
Mismatching parameters are set in the nozzle type data and the compo-
nent library data.
(Remedy 1) Check if proper components are used.
(Remedy 2) Check the vacuum pressure.
(Remedy 3) Check the parameters in the nozzle type data and the component li-
brary data.
02**2100** Error in Outward Length Inspection
02**2101** Cmponent Outward Length X is incorrect.
02**2102** Component Outward Length X is shorter than the tolerance.
02**2103** Component Outward Length X is longer than the tolerance.
02**2104** Component Outward Length Y is incorrect.
02**2105** Component Outward Length Y is shorter than the tolerance.
02**2106** Component Outward Length Y is longer than the tolerance.
02**2107** Component Outward Length X or Y is incorrect.
02**2108** Component Outward Length X or Y is shorter than the tolerance.
02**2109** Component Outward Length X or Y is longer than the tolerance.
(Cause 1) Wrong parameters are set in the "X [mm]" and "Y [mm]" text boxes of
"Mold size" and the "Mold size tolerance X [mm]" and "Mold size tolerance
Y [mm]" text boxes for the selected components.
(Remedy 1) Check the selected components and the parameters set in the "X [mm]"
and "Y [mm]" text boxes of "Mold size" and the "Mold size tolerance X
[mm]" and "Mold size tolerance Y [mm]" text boxes for the selected
components in the component library data.
Correct wrong parameters if they are set in the component library data.
X
Y
0511-002 2-188 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Fig. 4B22
Note

Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**2200** Error in Lead Inspection
02**2201** The number of leads is incorrect.
02**2202** The number of leads is small.
02**2203** The number of leads is large.
02**2204** The lead width is incorrect.
02**2205** The lead width is shorter than the tolerance.
02**2206** The lead width is longer than the tolerance.
02**2207** The lead length is incorrect.
02**2208** The lead length is shorter than the tolerance.
02**2209** The lead length is longer than the tolerance.
02**2210** The lead pitch is incorrect.
02**2211** The lead pitch is smaller than the tolerance.
02**2212** The lead pitch is larger than the tolerance.
02**2213** The lead position (LATL DIR) is incorrect.
02**2214** The lead position (LONG DIR) is incorrect.
(Cause 1)The results of the lead inspection differ from the parameters specified in
the component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
Correct wrong parameters if they are set in the component library data.
0511-002 2-189 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**2300** Error in Electrode (Ball) Inspection
02**2301** The Electrode(ball) position is incorrect.
02**2302** There is Electrode(ball) of the size outside permissible value.
(Cause 1) There is a difference between the results of the electrode (ball) inspec
tion of the selected component and the component library data.
(Remedy 1) Check the electrodes (balls) of the selected component and the compo-
nent library data.
Correct wrong parameters if they are set in the component library
data.
02**2400** Error in Polarity Detection.
02**2401** Failed in Polarity Detection.
02**2402** The detected polarity differs from specification.
(Cause 1)There is a difference between the results of the polarity determination of
the selected component and the component library data.
(Remedy 1) Check the polarity of the selected component and the component li
brary data.
Correct wrong parameters if they are set in the component library
data.
02**2900** Picked Posture Error
02**2901** The pick angular skew is big.
02**2902** The pick-up position has deviated greatly in X direction.
02**2903** The pick-up position has deviated greatly in Y direction.
02**2904** The pick-up position has deviated greately in X or Y direction.
(Cause 1)When a component is picked up, the pick-up positions (X and Y) and
angle have shifted greatly from the correct ones.
(Cause 2)When the tape is fed, a component is turned vertically.
(Remedy 1) Check the selected component and the tape feeder.
Check if the feeder (B) offset data is correct.
Check if the component library data is correct.
(Remedy 2) Check the selected component and the tape feeder.
0511-002 2-190 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures