4OM-1003-007.pdf - 第346页
Error ID ltem Description 650206 Nozzle Bypass Nozzle Level (Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the master nozzle in the of fset data. (Remedy 1) Check if a big value is …

(65 Head Origin Offset)
Error ID ltem Description
650101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
650201 Nozzle Bypass Nozzle Down Error (L)
650202 Nozzle Bypass Nozzle Down Error (H)
650203 Nozzle Bypass Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
650204 Nozzle Bypass Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
650205 Nozzle Bypass Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
0511-003 2-145 AIL01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
650206 Nozzle Bypass Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master level in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
650207 Nozzle Bypass Nozzle Drop
(Cause 1) The nozzle being used has dropped.
(Remedy 1) Check the pertinent nozzle.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
650208 Nozzle Bypass Dummy Nozzle
650209 Nozzle Bypass Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the "Head/Noz. Bypass" tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
65020a Nozzle Bypass Nozzle Change Error. (Cam lock action)
65020b Nozzle Bypass Nozzle Change Error. (Cam Free action)
65020c Nozzle Bypass Cam Origin Error.
65020d Nozzle Bypass Nozzle Teach Error.
65020e Nozzle Bypass Nozzle Posture Detection
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-146 AIL01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
650301 Head Skip Communication Error
650302 Head Skip Head Origin
650303 Head Skip Overtime Head Origin Return
650304 Head Skip Unselected Nozzle Drop
650305 Head Skip Dummy Nozzle
650306 Head Skip Manual Bypass
650307 Head Skip Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
650401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
650402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
650403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
650404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
650501 Master Head Offset Linear Measure System Was At High Position.
650502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0305-001 2-147 AIL01ETRP
3.3 Error IDs and Remedial Procedures