4OM-1003-007.pdf - 第179页
1.2 "CHECK" Windows 1.2.1 "CHECK" Windows When the machine is not reset to its normal condition after an operator makes an error operation or an error occurs in the operation system, a window like the…

1. Scope
1.1 Scope of Troubleshooting
The troubleshooting is composed as follows.
Error ID (6 digits)
Recognition Error ID (10 digits)
Fig. 4B1
0403-002 2-1
AIL01ETRP
1. Scope
Troubleshooting after
"CHECK" Window
Troubleshooting after
"Machine lnformation" Window
Easy Troubleshooting
Troubleshooting after
"ERROR" Window
Troubleshooting on
Component Pick and
Placements
This session describes the remedial procedures at
a "CHECK" window.
Refer to "1.2 "CHECK" Windows" for details.
This session describes the remedial procedures at
the "Machine lnformation" Window.
Refer to "1.3 Machine lnformation" for details.
This session describes the remedial procedures of
an error for which no error message is issued.
Refer to "2. Easy Troubleshooting" for details.
Various troubleshootings must be performed
according to the difference of error IDs and
recognition error IDs.
See Fig. 4B1.
Refer to "3. Troubleshooting after Error
Window (Error ID)" for details.
Refer to "4. Troubleshooting after Error
Window (Recognition Error ID)" for details.
This session describes the cause and remedy of
general errors in component pick and placements.
Refer to "5. Troubleshooting related to Component
Pick and Placements" for details.
Troubleshooting based on
Error ID (6 digits)
Troubleshooting based on
Recognition Error ID
(10 digits)

1.2 "CHECK" Windows
1.2.1 "CHECK" Windows
When the machine is not reset to its normal condition after an operator
makes an error operation or an error occurs in the operation system, a
window like the following opens.
Fig. 4B2 Example of "CHECK" Window
*1 Check Message
A check message is issued and displayed.
Refer to "1.2.2 List of Check Messages" for details.
*2 Display Field A
Displayed is the scope of the check message.
*3 Display Field B
Displayed are the details of the check message.
0511-002 2-2
AIL01ETRP
1.2 "CHECK" Windows
*1
*4
*3
*5
*2
Note

*4 [OK] Button
When pressed, this button closes the "CHECK" window.
*5 Saving the check message
The check message is saved as a production message.
••
••
• Reset Procedure from "CHECK" Window
(1) Take a note of the issued check message.
Be sure to take a note of the check message. If you forget the
contents of the message, the machine cannot be reset cor-
rectly to its normal condition.
(2) Press the [OK] button. The original window resumes.
(3) Follow the contents of the check message to reset the machine
correctly to its normal condition.
0305-001 2-3
AIL01ETRP
1.2 "CHECK" Windows
Note