Error ID ltem Description 610301 Head Bypass Communication Error 610302 Head Bypass Head Origin 610303 Head Bypass Overtime Head Origin Return 610304 Head Bypass Unselected Nozzle Drop 610305 Head Bypass Dummy Nozzle 610…

100%1 / 409
Error ID ltem Description
610206 Nozzle Bypass Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master level in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
610207 Nozzle Bypass Nozzle Drop
(Cause 1) The nozzle being used has dropped.
(Remedy 1) Check the pertinent nozzle.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
610208 Nozzle Bypass Dummy Nozzle
610209 Nozzle Bypass Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the “Head/Noz. Bypass” tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
61020a Nozzle Bypass Nozzle Change Error. (Cam lock action)
61020b Nozzle Bypass Nozzle Change Error. (Cam Free action)
61020c Nozzle Bypass Cam Origin Error.
61020d Nozzle Bypass Nozzle Teach Error.
61020e Nozzle Bypass Nozzle Posture Detection
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-130 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
610301 Head Bypass Communication Error
610302 Head Bypass Head Origin
610303 Head Bypass Overtime Head Origin Return
610304 Head Bypass Unselected Nozzle Drop
610305 Head Bypass Dummy Nozzle
610306 Head Bypass Manual Bypass
610307 Head Bypass Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
610401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
610402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
610403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
610404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
610501 Master Head Offset Linear Masure System Was At High Position.
610502 Master Head Offset Linear Masure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0403-002 2-131 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
610601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
610701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
610702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
610801 Recog. Data Teach Recognition Error Code.
610901 Trash Teach Error Code. Recognition Error Code.
610a01 Gain Level Teach Error Recognition Error Code.
610b01 Nozzle Posture Level Nozzle Posture Level Was Less Than Low Limit.
Note: Refer to "4. Troubleshooting after Error Window (Recognition Error ID)" for details.
3.3 Error IDs and Remedial Procedures
0511-002 2-132 AIL01ETRP