4OM-1003-007.pdf - 第387页

4.3.5 V arious T each Errors AA BB C DDDDD Detail Code Secondary Error Classification (0) Primary Error Classification (0 to 5) Classification (10) of Recognition Functions When an error ID other than the described ones …

100%1 / 409
4.3.4 Nozzle Recognition Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (1 to 4)
Primary Error Classification (0)
Classification (04) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B17
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0400100000 Nozzle Not Detected.
0400200000 Nozzle size has exceeded the allowable range.
0400300000 Nozzle position has exceeded the allowable range.
0400400000 Garbage and dirt are in a nozzle tip or a nozzle taper part.
(Cause 1) The nozzle is attached abnormally.
(Cause 2) The nozzle type data is abnormal.
(Remedy 1) Attach the nozzle correctly.
(Remedy 2) Check the nozzle type data. If necessary, correct it.
0511-003 2-198 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Note
4.3.5 Various Teach Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (0)
Primary Error Classification (0 to 5)
Classification (10) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B18
Recognition Error ID Recognition Error Contents, Cause, and Remedy
1001000000 Failed in Detection of Camera Position during Camera Offset Teaching Operation.
(Cause 1) Set the jig correctly.
(Remedy 1) Set the jig correctly.
Or, contact our service personnel for some advice.
1002011001 Error in Camera Sensitivity Check Operation
The brightness is not suitable for the adjustment.
(Cause 1) The camera sensitivity may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003011001 Error in Lighting Intensity Data (Back Lighting)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003011002 Error in Lighting System (Back Lighting)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
0511-002 2-199 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Note
Recognition Error ID Recognition Error Contents, Cause, and Remedy
1003011005 Error in Lighting Intensity Data (Back Lighting)
The diffusion plate with which brightness differs is attached.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003012001 Error in Lighting Intensity Data (Front Lighting 1)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003012002 Error in Lighting System (Front Lighting 1)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003013001 Error in Lighting Intensity Data (Front Lighting 2)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003013002 Error in Lighting System (Front Lighting 2)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003013003 Error in Camera Sensitivity (Front Lighting 2)
Please adjust camera sensitivity.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
0511-002 2-200 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures