4OM-1003-007.pdf - 第388页
Recognition Error ID Recognition Error Contents, Cause, and Remedy 100301 1005 Error in Lighting Intensity Data (Back Lighting) The diffusion plate with which brightness dif fers is attached. (Cause 1) The lighting syste…

4.3.5 Various Teach Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (0)
Primary Error Classification (0 to 5)
Classification (10) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B18
Recognition Error ID Recognition Error Contents, Cause, and Remedy
1001000000 Failed in Detection of Camera Position during Camera Offset Teaching Operation.
(Cause 1) Set the jig correctly.
(Remedy 1) Set the jig correctly.
Or, contact our service personnel for some advice.
1002011001 Error in Camera Sensitivity Check Operation
The brightness is not suitable for the adjustment.
(Cause 1) The camera sensitivity may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003011001 Error in Lighting Intensity Data (Back Lighting)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003011002 Error in Lighting System (Back Lighting)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
0511-002 2-199 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Note

Recognition Error ID Recognition Error Contents, Cause, and Remedy
1003011005 Error in Lighting Intensity Data (Back Lighting)
The diffusion plate with which brightness differs is attached.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003012001 Error in Lighting Intensity Data (Front Lighting 1)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003012002 Error in Lighting System (Front Lighting 1)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003013001 Error in Lighting Intensity Data (Front Lighting 2)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003013002 Error in Lighting System (Front Lighting 2)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003013003 Error in Camera Sensitivity (Front Lighting 2)
Please adjust camera sensitivity.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
0511-002 2-200 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Recognition Error Contents, Cause, and Remedy
1003013004 Error in Instruction Object.
The instruction object is not suitable.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
1003014001 Error in Lighting Intensity Data (Front Lighting 3)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
1003014002 Error in Lighting System (Front Lighting 3)
Failed in Teaching Operation for Assumed Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
0511-002 2-201 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures