4OM-1003-007.pdf - 第196页
1.3 Machine lnformation 051 1-002 2-18 AIL01ETRP Check Code Display Section A Display Section 801208 Stat Auto Head Unselected Nozzle Drop. Recovery 801209 Stat Auto Head Component output error(Pickup error) is detected …

Check Code Display Section A Display Section B
801001 Auto Offset Teach Auto offset teach mode start.(this prcs. Completed)
Information
801002 Auto Offset Teach Nozzle offset error.
Information
801003 Auto Offset Teach Nozzle Dirt Detection. If dirt has adhered, there is a possibility
Information that it may become impossible to recognize. Please remove the
ring lighting glass upper surface, a diffusion board, and the dirt
adhering to the nozzle.
801004 Auto Offset Teach Gain Level Teach Error.
Information
801005 Auto Offset Teach "Camera Dirt Detection. If dirt has adhered, there is a possibil-
ity Information that it may become impossible to recognize.
Please remove the ring lighting glass upper surface, a diffusion
board, and the dirt adhering to the nozzle."
801006 Auto Offset Teach Nozzle center error.
Information
801007 Auto Offset Teach Nozzle origin error.
Information
801008 Auto Offset Teach Nozzle Posture Level
Information
801101 Feeder Carriage Return to order of priority carriage.
Priority Mode
801201 Start Auto Head Cpu Communication error occurred.(CPU2-CPU3)
Recovery
801202 Start Auto Head Head cam origin return action not complete.(Not CAM ORIGIN
Recovery position)
801203 Start Auto Head Head Driver communication is time out.(from cpu3 job)
Recovery
801204 Start Auto Head Nozzle change action not complete.(cam lock action NG)
Recovery
801205 Start Auto Head Head cam position return action not complete.
Recovery
801206 Start Auto Head Nozzle change action not complete.(cam free action NG)
Recovery
801207 Start Auto Head Nozzle change action not complete.(Not CAM ORIGIN position)
Recovery
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
1.3 Machine lnformation
0511-001 2-17-1 AIL01ETRP

1.3 Machine lnformation
0511-002 2-18 AIL01ETRP
Check Code Display Section A Display Section
801208 Stat Auto Head Unselected Nozzle Drop.
Recovery
801209 Stat Auto Head Component output error(Pickup error) is detected by nozzle level
Recovery was position. ;Nozzle posture detection
80120a Stat Auto Head The selected nozzle was not at position. ;Nozzle posture detec-
Recovery tion
80120b Stat Auto Head Component output error(Others) is detected by nozzle level was
Recovery position. ;Nozzle posture detection
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
801301 Pickup Position Feedback value out of range. Please check feeder.
Feedback
801401 Pickup Level Data Calculated data out of range. Please check library data and offset
data.
801402 Placement Level Calculated data out of range. Please check library data and offset
Data data.
801501 Feeder Index Production operation was interrupted in the middle of feeder index
Position operation. Please check a position.
801502 Feeder Index The feeder carriage was returned to the home position in the middle
Position of feeder index operation.
Please check a feeder index position.
801601 Product Restart Restart production with semi-auto(after specified step) mode.
801602 Product Restart Restart production with warm start mode.
801603 Product Restart Restart production with warm start mode after EMER stop. Ma-
chine will stop after placement complete. Please confirm PCB af-
terward.
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.

Check Code Display Section A Display Section B
801701 Teach Nozzle Nozzle Down Error.(L)
Bypass
801702 Teach Nozzle Nozzle Down Error.(H)
Bypass
801703 Teach Nozzle Recognition Teach Error.
Bypass
801704 Teach Nozzle Teach Error Data.
Bypass
801705 Teach Nozzle Lighting Check.
Bypass
801706 Teach Nozzle Nozzle Level.
Bypass
801707 Teach Nozzle Nozzle Drop
Bypass
801708 Teach Nozzle Dummy Nozzle.
Bypass
801709 Teach Nozzle Manual Bypass.
Bypass
80170a Teach Nozzle Nozzle Change Error.(Cam lock action)
Bypass
80170b Teach Nozzle Nozzle Change Error.(Cam Free action)
Bypass
80170c Teach Nozzle Cam Origin Error.
Bypass
80170d Teach Nozzle Nozzle Teach Error.
Bypass
80170e Teach Nozzle Nozzle Posture Detection
Bypass
(Contents) The nozzle to be taught was bypassed.
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
1.3 Machine lnformation
0511-002 2-19 AIL01ETRP