4OM-1003-007.pdf - 第320页
(4f Program Error) Error ID ltem Description 4f0101 PROGRAM ERROR Error in Sequence Controller! Operation Not Secured 4f0201 PROGRAM ERROR Error in Polling T ask (CPU2)! Operation Not Secured 4f0202 PROGRAM ERROR Error i…

(4c Unit P.C.B. B.B.R. Mode)
Error ID ltem Description
4c0101 B.B.R. All unit P.C.B.’s ware detected as defective.
(P.C.B. on XY-Table)
4c0102 B.B.R. All unit P.C.B.’s ware detected as defective.
(P.C.B. on Transfer Conveyor)
4c0201 Unit P.C.B. B.B.R. Information Not exist available information.
(P.C.B. on Transfer Conveyor)
4c0202 Unit P.C.B. B.B.R. Information Not exist available information.
(P.C.B. on Transfer XY-Table)
4c0203 Unit P.C.B. B.B.R. Information Communication data is illegal information.
4c0301 Unit P.C.B. B.B.R. Product P.C.B count is complete.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Follow the described instructions and reset the machine to its normal condition
.
0511-003 2-120 AIL01ETRP
3.3 Error IDs and Remedial Procedures

(4f Program Error)
Error ID ltem Description
4f0101 PROGRAM ERROR Error in Sequence Controller! Operation Not Secured
4f0201 PROGRAM ERROR Error in Polling Task (CPU2)! Operation Not Secured
4f0202 PROGRAM ERROR Error in Polling Task (CPU3)! Operation Not Secured
4f0203 PROGRAM ERROR Error in Pick-Up Sequence!
Error Sequence is started Recovery mode.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0511-003 2-121 AIL01ETRP

(50 Pickup Error)
Error ID ltem Description
500101 Comp. Missing(Sensor)
(Cause 1) The machine stopped running because the linear measure detection sensor de-
tected the "Component Missing (Sensor)" error continuously.
Ref.: When "2" is set in the "1" text box of "Error process" in the component library
data, it means that a pick-up error occurred continuously twice on the same
feeder No.
Note: This detection cannot be made when "less than 0.15 mm" is set in the "t" text
box of "Component thickness" in the component library data or the carrier
data.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Check "Step" and "Feeder No." where an error has occurred.
(2) Press the [RETURN] and [ALL] button (entitled "ZERO"). After that, check
the following items related to the pertinent feeder No.
• Check if some components are left in the tape feeder.
• Check if the cover tape is peeled off normally.
• Check if the tape feeder is installed correctly on the feeder carriage.
• Check if the tape feeder is loaded with correct components.
• Check if some components are left in the carrier tape.
If left, be sure to remove them to protect the cutter blades from being
damaged.
• Check if the vacuum nozzle is not clogged or proper vacuum pressure is
applied.
(3) After taking the required countermeasures, re-start the production.
500201 Comp. Vertical(Sensor)
(Cause 1) The machine stopped running because the linear measure detection sensor de-
tected the "Vertical Component (Sensor)" error continuously.
Ref.: When "9" is set in the "2" text box of "Error process" in the component library
data, it means that a pick-up error occurred continuously 9 times on the same
feeder No.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Check "Step" and "Feeder No." where an error has occurred.
(2) Press the [RETURN] and [ALL] button (entitled "ZERO"). After that, check
the following items related to the pertinent feeder No.
• Check if the tape feeder is loaded with correct components.
• Check the selected components and the parameter set in the "Vertical
cmpnt data[mm]" text box in the component library data. If a wrong pa-
rameter is set, correct it.
Note: Check the parameter set as vertical component data in the "CMPNT
CARRIAGE DATA EDIT" window.
(3) After taking the required countermeasures, re-start the production.
0511-003 2-122 AIL01ETRP
3.3 Error IDs and Remedial Procedures