4OM-1003-007.pdf - 第371页
Recognition Error ID Recognition Error Contents, Cause, and Remedy 0139320003 "Component Library Recog Level" Not Supported! 0139320004 Component Library Front ltg algo Not Supported! 0139320005 Component Libra…

Recognition Error ID Recognition Error Contents, Cause, and Remedy
0139314112 Error in "Component Library Elctd Dim1" Data
0139314113 Error in "Component Library Elctd Dim2" Data
0139314213 Error in "Component Library Elctd Gp Posn X or Y" Data
0139314214 Error in "Component Library Elctd Col Pitch" Data
0139314215 Error in "Component Library Row Pitch" Data
0139314216 Error in "Component Library Elctd # of Cols" Data
0139314217 Error in "Component Library Elctd # of Rows" Data
0139314221 Error in "Component Library Elctd Missing Elctd No" Data
0139314231 Error in "Component Library Elctd Missing Std Col" Data
0139314232 Error in "Component Library Elctd Missing Std Row" Data
0139314233 Error in "Component Library Elctd # of Missing Cols" Data
0139314234 Error in "Component Library Elctd # of Missing Rows" Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0511-002 2-182 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Recognition Error Contents, Cause, and Remedy
0139320003 "Component Library Recog Level" Not Supported!
0139320004 Component Library Front ltg algo Not Supported!
0139320005 Component Library Back ltg algo Not Supported!
0139320007 "Component Library View Range Set" Not Supported!
0139322001 "Component Library Polarity Detn" Not Supported!
0139322002 "Component Library Polarity Inspection Method" Not Supported!
0139322003 "Component Library Polarity Detn Inspection Pos X or Y" Not Supported!
0139322004 "Component Library Polarity Detn Inspection Range" Not Supported!
0139323001 "Component Library Upper/Lower Surface Detn" Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139324102 Error in "Component Library Mold Size Tolerance X or Y" Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139324201 "Component Library Outward Length Detn" Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0511-002 2-183 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Recognition Error Contents, Cause, and Remedy
0139324202 Error in "Component Library Outward Length Tol" Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139325101 "Component Library Lead Width Detn" Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139325102 "Component Library Lead Posn (Latl Dir) Detn" Not Supported!
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139325201 "Component Library Lead Posn (Latl Dir) Detn" Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139325202 Error in "Component Library Lead Posn (Latl Dir) Tol" Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0511-002 2-184 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures