4OM-1003-007.pdf - 第383页

051 1-002 Recognition Error ID Recognition Error Contents, Cause, and Remedy 02**8000** Data Error 02**8001** Data Error in Process 02**8002** Error in Lighting Data (Cause 1) Self-Diagnostics Error Message (Remedy 1) Co…

100%1 / 409
Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**3600** Error in Electrode(ball) Detection
02**3601** No Electrode(ball) Detected.
02**3602** Since a sufficient number of Electrode(ball) were undetectable, it cannot position.
02**3603** There is Electrode(ball) undetectable in the line or sequence of a group outside.
02**3604** Electrode(ball) which is in agreement with data was undetectable.
02**3605** Electrode(ball) which is not specified was detected.
(Cause 1) There is a difference between the results of the electrode (ball) inspection
of the selected component and the component library data.
(Remedy 1) Check the electrodes (balls) of the selected component and the compo-
nent library data.
Correct wrong parameters if they are set in the component library
data.
02**4100** Reverse Check Error
02**4101** The component is reversed.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
02**4200** Error in Pick-up Position Detection
02**4201** The pick-up position has deviated greatly in X direction.
02**4202** The pick-up position has deviated greatly in Y direction.
02**4203** The pick angular skew is big.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
0511-002 2-194 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
0511-002
Recognition Error ID Recognition Error Contents, Cause, and Remedy
02**8000** Data Error
02**8001** Data Error in Process
02**8002** Error in Lighting Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
02**9000** Other Errors
02**9001** Internal Processing Error
02**9002** Impossible to set the detection window.
02**9003** Impossible to set the window for arrayed lead end detection.
02 **9004** Impossible to set the window for lead detection at the corner.
02**9005** Impossible to set the window for lead detection.
02**9006** Angle Calculation Impossible.
02**9007** Internal Processing Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
4.3 Recognition Error IDs and Remedial Procedures
0511-002 2-195 AIL01ETRP
4.3.3 P.E.C. Recognition Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (1 to 4)
Primary Error Classification (0 to 1)
Classification (03) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B16
Recognition Error ID Recognition Error Contents, Cause, and Remedy
0300100000 Specified Mark Not Found in Recognizable Range.
0300200000 Unstable Image around Fiducial Mark.
0300300000 Extensive Error in Similitude of Mark Shape.
0300400000 Extensive Error in Similitude of Mark Shape or Size.
0301100000 Specified Mark Not Found in Recognizable Range.
(Cause 1)The fiducial mark and the fiducial mark coordinates X and Y or the mark
data are not suitable.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) When the [RETURN] button is pressed, the following recognition
window appears.
Fig. 4B26 Sample Display of Recognition Window
(Continue to the next page. )
0511-002 2-196 AIL01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Note