3.3.2 Process Errors (40 Safety Device) Error ID Item Description 400101 Abnormal Front Safety Door The machine’ s front safety door(lower) is open. 400102 Abnormal Front Safety Door The rotary hand wheel has been insert…

100%1 / 409
0511-002 2-92 AIL01ETRP
3.3 Error IDs and Remedial Procedures
(16 R2 Conveyor)
Error ID Item Description
160601 R2 Conveyor Communication The controller can not run.
160602 R2 Conveyor Communication Controller interior is out of order.
160603 R2 Conveyor Communication Controller in communication error condition.
160604 R2 Conveyor Communication Controller incomplete resulting in an overtime alarm.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
160701 R2 Conveyor Overtime The R2 Conveyor was not completely sent.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3.2 Process Errors
(40 Safety Device)
Error ID Item Description
400101 Abnormal Front Safety Door The machine’s front safety door(lower) is open.
400102 Abnormal Front Safety Door The rotary hand wheel has been inserted.
(Cause 1) The front safety door was opened with the machine in the operation mode.
(Cause 2) The cam hand-rotating wheel is inserted into the motor shaft of the rotary turret.
(Remedy 1) Press the [RETURN] button to cancel the error display and press the [POWER]
button again. After the machine is powered up, perform the zeroing operation on
all axes.
(Remedy 2) Detach the cam hand-rotating wheel.
400207 Fdr.Crg. Axis Safety Guard The fdr.crg. Axis safety guard (a) is open.
400208 Fdr.Crg. Axis Safety Guard The fdr.crg. Axis safety guard (b) is open.
400211 Fdr.Crg. Axis Safety Guard The fdr.crg. #1 home location safety guard is open.
400216 Fdr.Crg. Axis Safety Guard The fdr.crg. #2 home location safety guard is open.
(Cause 1) The safety cover was opened while the feeder carriage was moving.
(Cause 2) The [START] button was pressed with the safety cover being open.
(Remedy 1) Close the safety cover.
(Remedy 2) Press the [RETURN] button to cancel the error display and then zero all axes.
400301 Load Power Circuit The [emergency stop] button was pressed.
Refer to "2.3 [EMERGENCY STOP] Switch Pressed" for "(Ca
use 1)" and "(Remedy 1)".
0511-002 2-93 AIL01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
400302 Load Power Circuit The air pressure is too low.
(Cause 1) The main air pressure has dropped below the specified one.
Fig. 4B18
(Remedy 1) Adjust the pressure to the correct one.
Turn Knob (1) to adjust the main air pressure to the specified one (0.5 MPa
(5.1kgf/cm
2
)).
400303 Load Power Circuit Circuit porotector is active.
(Cause 1) The circuit breaker in the machine was activated.
(Remedy 1) Consult our service personnel for details.
400304 Load Power Circuit The machine’s front safety door is open.
(Cause 1) The front safety door was opened.
(Remedy 1) Close the front safety door after pressing the [RETURN] button and zero all
axes. Then, re-start the operation.
0511-003 2-94 AIL01ETRP