4OM-1003-007.pdf - 第318页
051 1-001 2-119-1 AIL01ETRP Error ID ltem Description 4b030c ILLEGAL OPERA TION P .C.B. REMOVE FROM INPUT CONVEYOR. (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation. When the m…

Error ID ltem Description
4b0306 ILLEGAL OPERATION P.C.B. WAS TOOK ON X/Y TABLE.
(Cause 1) The P.C.B. on the X/Y table is improper.
Check it.
(Remedy 1) Remove the improper P.C.B. and start the production, using a proper P.C.B.
4b0307 ILLEGAL OPERATION SET-UP CAN NOT MOVE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
4b0308 ILLEGAL OPERATION P.C.B. WAS TOOK ON INPUT BUFFER CONVEYOR.
(Cause 1) An improper P.C.B. exists on the input conveyor.
(Remedy 1) Remove the improper PCB on the input conveyor and restart the production.
4b0309 ILLEGAL OPERATION P.C.B. WAS TOOK ON INPUT CONVEYOR.
(Cause 1) An improper P.C.B. exists on the transfer conveyor.
(Remedy 1) Remove the improper P.C.B. on the transfer conveyor and re-start the produc-
tion.
4b030a ILLEGAL OPERATION P.C.B. WAS TOOK ON OUTPUT CONVEYOR.
(Cause 1) An improper P.C.B. exists on the output conveyor.
(Remedy 1) Remove the improper P.C.B. on the output conveyor and re-start the production.
4b030b ILLEGAL OPERATION P.C.B. REMOVE FROM INPUT BUFFER CONVEYOR.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0511-003 2-119 AIL01ETRP
3.3 Error IDs and Remedial Procedures

0511-001 2-119-1 AIL01ETRP
Error ID ltem Description
4b030c ILLEGAL OPERATION P.C.B. REMOVE FROM INPUT CONVEYOR.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
4b030d ILLEGAL OPERATION P.C.B. REMOVE FROM OUTPUT CONVEYOR.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
4b0401 Machine Interface Signal Check the P.C.B. input machine on conveyor.
Input machine P.C.B. existence signal turn to available for
setup.
4b0402 Machine Interface Signal Check the P.C.B. output machine on conveyor.
Output machine P.C.B. existence signal turn to available for
setup.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
4b0501 XY table chute X/Y Chute Lower Limit not exist.
4b0502 XY table chute X/Y Chute Upper Limit not exist.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.

(4c Unit P.C.B. B.B.R. Mode)
Error ID ltem Description
4c0101 B.B.R. All unit P.C.B.’s ware detected as defective.
(P.C.B. on XY-Table)
4c0102 B.B.R. All unit P.C.B.’s ware detected as defective.
(P.C.B. on Transfer Conveyor)
4c0201 Unit P.C.B. B.B.R. Information Not exist available information.
(P.C.B. on Transfer Conveyor)
4c0202 Unit P.C.B. B.B.R. Information Not exist available information.
(P.C.B. on Transfer XY-Table)
4c0203 Unit P.C.B. B.B.R. Information Communication data is illegal information.
4c0301 Unit P.C.B. B.B.R. Product P.C.B count is complete.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Follow the described instructions and reset the machine to its normal condition
.
0511-003 2-120 AIL01ETRP
3.3 Error IDs and Remedial Procedures