88242361-04-01 Vol 1 DEK TQ TECHNICAL REFERENCE (1).pdfPDFA.pdf - 第128页

8 SQUEEGEE MODULE 8.1 OVERVIEW 128 TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 To prevent a collision with the drip tray,a short drip tray ( 360mm ) should be used in conjunction with a stencil size of 6320mm ( 24.409&quot…

100%1 / 194
8 SQUEEGEE MODULE
8.1 OVERVIEW
TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 127
8.1.3 Paste Deflectors
Paste deflectors may be used to keep the print medium in front of the squeegees.
1 Paste Deflector Securing Screws 3 Squeegee
2 Paste Deflectors
8.1.4 Squeegee Drip Tray
1 Air Inlet to Extend Drip Tray 4 Drip Tray
2 Drip Tray Pneumatic Actuator 5 Air Inlet to Retract Drip Tray
3 Rubber Bumper Stop 6 Drip Tray Retracted Sensor
The squeegee drip tray mechanism is secured below the print carriage and behind the squeegee
mechanism. The drip tray’s pneumatic actuator extends the drip tray below the squeegees to pre-
vent print medium from dripping onto the stencil during print carriage initialisation or auto stencil
loading. Magnets hold the drip tray in place and can easily be unhooked for easy cleaning.
There are two sizes of drip tray:
460mm
360mm
8 SQUEEGEE MODULE
8.1 OVERVIEW
128 TECHNICAL REFERENCE MANUAL DEK TQ 04/2021
To prevent a collision with the drip tray,a short drip tray (360mm) should be used in conjunction
with a stencil size of 6320mm
(24.409") or less.
The drip tray retracted sensor is used by software to check that the pneumatic actuator has retrac-
ted the drip tray fully before lowering the squeegees.
The rubber bumper stop prevents a collision with the stencil load mechanism when retracting.
8 SQUEEGEE MODULE
8.2 ELECTRICAL SCHEMATIC
TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 129
8.2 ELECTRICAL SCHEMATIC
M
M
Front
Squeegee
MTR28
Rear
Squeegee
MTR29
Extended Power Module
EPM2-1
Extended Power Module
EPM2-2
Machine Controller
Controller Power Module
(CPM)
J4 EPM2PL15EPM2PL13
Fibre
Optic
Links
Ribbon Cables
SIO Link
Cables
EPM2PL16EPM2PL14
4SK10
4SK11
J4
ESIO-4
ESIO-5
ESIO-3
ESIO-3: Breakout A
ADC/DAC
Board 5
Conditioning Board
IO1
IO2
IO4 IO5
3ASK2
M73PL5
5PL3
M73SK1
Front
Squeegee
4SE8
Rear
Squeegee
4SE9
Home
Sensor
Home
Sensor
3ASK23
3ASK24
3ASK13
3ASK14
Squeegee
Load Cell
5SE1
M73PL4
M73PL2
Connector for break-off
temperature and humidity board
5PL6
°C
%RH