9 PASTE DISPENSER SYSTEM 9.4 REPLACEMENT PROCEDURES TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 149 9.4 REPLACEMENT PROCEDURES 9.4.1 Paste Dispenser Changeover The paste dispenser allows for the use of paste jars or cartri…

9 PASTE DISPENSER SYSTEM
9.3 ADJUSTMENTS AND SETTINGS
148 TECHNICAL REFERENCE MANUAL DEK TQ 04/2021
9.3.3 Paste Level Sensor (Jar)
9.3.3.1 Mechanical Setting
1. Open the front cover.
2. Check the 24mm measurement between the end of the paste jar low level reed switch (1) and
the top of the paste jar cylinder support plate (3). The reed switch is located in the paste jar
cylinder (2).
24mm
2
3
1

9 PASTE DISPENSER SYSTEM
9.4 REPLACEMENT PROCEDURES
TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 149
9.4 REPLACEMENT PROCEDURES
9.4.1 Paste Dispenser Changeover
The paste dispenser allows for the use of paste jars or cartridges via interchangeable paste dis-
penser assemblies. The following procedures are used to change from one to the other.
9.4.1.1 Cartridge to Jar
1. Select the Changeover tab.
2. Select Start Changeover.
3. Select Continue.
4. Select Carriage To Rear.
5. Select Menu.
6. Select Shut Down.
7. Open the front cover.
8. Ensure that the stencil has been removed.
9. Switch the mains isolator to OFF.
10. Remove the front panel.
11. Turn the pneumatic lockout switch to EXH.
12. Remove the upper left hand side panel.
13. Disconnect the paste cartridge caps pneumatic quick release connector (1) from the paste
dispenser.
1
14. Open the paste cartridge cover and remove the paste cartridge from the paste dispenser.

9 PASTE DISPENSER SYSTEM
9.4 REPLACEMENT PROCEDURES
150 TECHNICAL REFERENCE MANUAL DEK TQ 04/2021
15. Remove and clean the paste drip tray (1).
1
16. Ensure that any spilled paste is removed from the surfaces on and around the paste dis-
penser.
17. Disconnect the three pneumatic connectors and unscrew and pull-up the electrical connector
plug.